Owner`s manual
18
Spa Start-up
Filling the Spa with Water
4) Fill the spa to the bottom of the pillows.
Note: DO NOT OVER-FILL YOUR TUB!
5) With the front panel off, verify there are no leaks at the pump union.
Note: Pump unions can become loose during shipping. Verify that
there are no leaks during filling of the spa.
6) Replace both filters.
Turning the Power On
Turn the power to the spa on at the main circuit breaker. Verify that your
spa has no error codes. (See page 33) Verify that there is good water
circulation in the spa. The pump will initially come on for 5 minutes and
cycle through each pump for one minute on each pump at start up.
Verifying Water Circulation
1) Open all the jets.
2) Press the Jets 1/2/3 button to turn the pumps on or off.
3) Make sure each seat has water flow.
19
Testing the GFCI Breaker
NOTE: The electrical service panel for your spa should be equipped
with a GFCI breaker. To avoid the risk of electrical shock, perform
the following safety test before each use of your spa.
1) Make sure the power is turned on at the electrical service panel.
2) Turn on the GFCI breaker. If the breaker stays on, it is functioning
properly.
Danger Risk of Electrical Shock
If the GFCI breaker fails to operate as described, there is a possibility of
an electric shock if the spa is used. Shut off the power at the main elec-
trical service panel until the source of the problem has been identified