Specifications

- 58 -
PANNER
Delay
(Predelay
± 1 ms)
Size
(Predelay
± 50 ms)
Regen Decay
(Fade
Time)
Shape
(LFO
Shape)
Pitch
(LFO
Offset)
Speed
(LFO
Speed)
Width
(LFO
Width)
Special
(*see below)
Vocal
0–1000ms 0–1000ms 0–100 1–7 1–11 0–10.5Hz 0–100% Threshold
Instrument
0–1000ms 0–1000ms 1–7 1–11 0–10.5Hz 0–100%
Concert
0–1000ms 0–1000ms 1–7 1–11 0–10.5Hz 0–100%
Gated
0–1000ms 0–1000ms 1–7 1–11 0–10.5Hz 0–100% Threshold
Ambient
0–1000ms 0–1000ms 1–7 0–10.5Hz 0–100% Diff. factor
Dynamic
0–1000ms 0–1000ms 1–7 1–11 0–10.5Hz 0–100% Threshold
PANNER PARAMETERS:
Delay: Changes the predelay time in
±
1 millisecond steps. The total amount of predelay is 1 second (1000 ms.)
Size: Changes the predelay time in
±
50 millisecond steps.
Regen: (Not used.)
Decay: This parameter is used in Vocal class and sets the amount of time it
takes the effect to fade in and out after the Threshold level is crossed.
A graph of this control’s action is on page 66.
Shape: Selects the LFO shape. Use the LFO Shapes table to match the
parameter’s value with an LFO waveform. Also, see page 65 for graphs
of the various LFOs.
Pitch: Controls the LFO phase difference (in 30° increments) between the two outputs of an
engine group (Outputs #1 and #2, or Outputs #3 and #4). A setting ofcreates a
normal panner where one channel’s LFO starts at 0° (low) and the other channel’s
LFO starts at 180° (high). Any setting other than 0° will offset the second channel’s
LFO by that many degrees. (See the LFO Offset table.) Use this control to create
uneven spin effects.
Note: An offset of 180° is not allowed since that would turn the panning effect into a
tremolo effect, where one channel’s LFO would start at 0° (low) and the other
channel’s LFO, offset by 180°, would start at 360° (also equal to 0°, or low). Both
channels’ level would rise and fall at the same time. To obtain an offset of 180°, use
the actual Tremolo effect (see page 54).
Speed: Sets the speed of the LFO between 0 and 10.5 cycles per second (Hz.)
LFO Shapes
1Sine
2 Triangle
3 Rectified Sine
4 Inverted Rectified Sine
5 Square
6Ramp
7 Inverted Ramp
LFO Offset
10
°
230
°
360
°
490
°
5 120
°
6 150
°
7 210
°
8 240
°
9 270
°
10 300
°
11 330
°