The SC system is ready to use from the factory. It is shipped from
the factory with a default (factory) program. The factory program-
ming for model SC 800 consists of one (1) fire zone and seven (7)
burglary zones. For model SC1600 the factory programming
consists of two (2) fire zones and fourteen (14) burglary zones. The
zone configuration can be individually reprogrammed from the SK1L
keypad or by using the ScanPro Downloader Software to suit
whatever zone options are necessary. Programming
cannotcannot
cannotcannot
cannot be
performed with the
EKP1EKP1
EKP1EKP1
EKP1 LED Keypad. User 16 may be additionally
programmed for keyswitch operation. There are four (4) individual
timers for E/E delay zones. Programmed loop response is available
from 10 milliseconds to 500 milliseconds.
The built in digital communicator can be programmed for today’s
most popular reporting formats.
See programming worksheet for Factory Default details.
1.21.2
1.21.2
1.2
ZONE PROGRAMMING OPTIONSZONE PROGRAMMING OPTIONS
ZONE PROGRAMMING OPTIONSZONE PROGRAMMING OPTIONS
ZONE PROGRAMMING OPTIONS
ZONEZONE
ZONEZONE
ZONE
ZONEZONE
ZONEZONE
ZONE
SUB FUNCTIONSUB FUNCTION
SUB FUNCTIONSUB FUNCTION
SUB FUNCTION
TYPETYPE
TYPETYPE
TYPE
FUNCTIONSFUNCTIONS
FUNCTIONSFUNCTIONS
FUNCTIONS
AA
AA
A
VV
VV
V
AILABLEAILABLE
AILABLEAILABLE
AILABLE
BURGLARY E/E 1 Bypass zone
E/E 2 Chime zone
E/E 3 Day/Night trouble
E/E 4 Loop response time
Instant Swinger rejection
Interior 1
Interior 2
Follower
FIRE Audible Loop response time Swinger
rejection Trouble
24 HOUR Silent Bypassable
Audible Loop response time Swinger
rejection Trouble
1.31.3
1.31.3
1.3
HARDHARD
HARDHARD
HARD
WW
WW
W
ARE OPTIONAL ITEMSARE OPTIONAL ITEMS
ARE OPTIONAL ITEMSARE OPTIONAL ITEMS
ARE OPTIONAL ITEMS
EKP1 -EKP1 -
EKP1 -EKP1 -
EKP1 - This is an LED keypad that can be used in the SC800
system. It is capable of showing zone status for only zones 1-8. It
is capable of many of the normal operations but
notnot
notnot
not able to function
as a keypad programmer. The operations that are
NONO
NONO
NO
T T
T T
T usable with
this keypad are also indicated on page (i).
SK1L - SK1L -
SK1L - SK1L -
SK1L - This is an LCD keypad that can be used in the SC800 and
the SC1600 systems. It has
fullfull
fullfull
full capabilities for operating and
programming the systems it is attached to. A variety of International
versions of this keypad are also available that have User/Installer
messages in different languages.
Four of any combinations of the keypads are the maximum per
installation.
DOB - DOB -
DOB - DOB -
DOB - This is the
DD
DD
Data
OO
OO
Output
BB
BB
Board. It can be used as any of five
output devices. These range from Zone Alarm memory devices to
a printer interface, to a Status Output device, to a Bell Module. The
latter three are explained in detail in the programming detail for Item
30.
POB-1 -POB-1 -
POB-1 -POB-1 -
POB-1 - The POB-1 kit can also be used to interface an on-site
parallel printer to the SC800/1600 alarm control panels. It consists
of a PCB and Interface cable along with mounting hardware. The
PCB must be used in the stack as specified in the instructions.
LC1 -LC1 -
LC1 -LC1 -
LC1 - This is the Telephone Line cut module. It is designed to sense
for a drop in voltage below 3 volts for a time period of 30 seconds +/
- 15 seconds. Once activated it turns on a Form "C" relay that can
be used for a local bell, piezo or even a wireless transmitter to
transmit to a neighbor or radio communicator in case of telephone
line loss.
FM2000 - FM2000 -
FM2000 - FM2000 -
FM2000 - This is a Two Wire smoke detector module. The SC system
was originally designed to accomodate four wire smoke detectors.
A maximum of ten, Two wire smoke detectors can be attached to one
of the FM2000 units. It comes with a 4.7K resistor that must be used
as the End-Of-Line resistor.
1.41.4
1.41.4
1.4
TIMER OPTIONSTIMER OPTIONS
TIMER OPTIONSTIMER OPTIONS
TIMER OPTIONS
The SC system has various timer options that can be changed to meet your various system needs. Listed below are the programmable
range for each timer option.
Bell shutoff time 2 - 30 minutes Zone reporting delay time 10-150 seconds
Zone response time 10mSecs to 500mSecs AC and Low battery reporting delay time 1-15 minutes
Test timer A Daily weekly monthly yearly reporting Entrance delay groups 1 through 4 10-150 seconds
Test timer B Daily weekly monthly yearly reporting Exit delay groups 1 through 4 10-150 seconds
Exception windows 15 min. - 225 minutes Opening exception window start 1 min. - 24 hours
Holiday schedule 1 - 10 holidays by month/day Closing exception window start 1 min. - 24 hours
Switched Output 0 - 23.75 hours Open/Close exception schedule 1-7 days