Programming instructions

33
SECTION 9: UL COMPLIANCE
9.1 RESIDENTIAL UL GRADE A
Follow the instruction below for compliance to:
Household Fire Warning System Units (UL985)
Household Burglary-Alarm System Units (UL1023)
Communicator System Units (UL1635)
HARDHARD
HARDHARD
HARD
WW
WW
W
ARE CONSIDERAARE CONSIDERA
ARE CONSIDERAARE CONSIDERA
ARE CONSIDERA
TIONSTIONS
TIONSTIONS
TIONS
1. Do not plug the Basler transformer into a receptacle controlled
by a switch.
2. All burglary zones must be terminated by a 2200 ohm 1/2 watt
resistor which is included with each unit. (P/N 123-000222).
3. All Fire type zones of protection must be terminated with an
end-of-line module which is sold separately (P/NEOL2200).
4. Use only UL listed 4-wire smoke detectors and EOL relay
modules. If the FM2000 is used, use a listed two-wire smoke
detector indicatedin the FM2000 Installation manual.
5. Use only UL listed bell or siren drivers. Maximum current for
the bell output should not exceed 300mA. Use terminals 7 and
9 as the bell output and use the single bell mode.
6. Maximum combined current draw for Auxiliary, Fire, Keypad,
and Auxiliary status outputs (Arm, Ready, Aud. Warning, and
Courtesy) is 600mA.
7. Use a Yuasa 12 volt 6 or 7AH battery. (Yuasa NP6-12 or NP7-
12).
8. When using the courtesy output, use only UL listed burglary
alarm interface modules. Suggested module: X10 BA-284.
9. If using the keyswitch input, use only UL listed momentary key
switches.
10. Keypads must be installed within the protected area.
11. A UL listed tamper switch must be installed on the control
panel cabinet.
12. UL listed SC800 Accessories:
EKP1 LED Keypad - Current draw=100mA
SK1L LCD Keypad - Current draw=100mA
EEM-8 zone expander
13. Use only UL listed annunciators for the Audible warning output.
14. Cut Jumper JPO.
PRPR
PRPR
PR
OGRAMMING CONSIDERAOGRAMMING CONSIDERA
OGRAMMING CONSIDERAOGRAMMING CONSIDERA
OGRAMMING CONSIDERA
TIONSTIONS
TIONSTIONS
TIONS
[ ] = Programming sheet locations
1. Maximum Exit time allowed is 60 seconds.
2. Maximum Entry time allowed is 40 seconds.
3.
Do not use the Auto-Arming feature in certified installations.
4. Program the panel to report to the Central Station on loss of AC
power and Low Battery. [Item 11 and 12]
5. Program all alarm sounding devices to operate for a minimum
of 4 minutes [Item 54]
6. Program the panel to report all Fire zone trouble conditions to
the Central Station [Item 47]
7. Dialing attempts for phone 1 & 2 must be a minimum of 5 and
a maximum of 10 attempts. [Item 4]
8. Program the (1 & 3) key pair for “Fire Power Reset”. [Item 30.2]
9. Test message interval must be programmed to 1 every 24
hours. [Item 30.2]
10. Single bell operation must be programmed in order to get a
pulsing output for Fire and a constant output on burglary
violations. [Item 33 - program anything other than 0]
11. Manual shutdown for fire zones (Latch Fire Bell operation) must
be enabled. [Item 30.1]
12. For correct dialer report prioritizing, Fire zones are to be
assigned to the lowest numbered zones, Panics on the next
numbered zones, and burglary zones on the highest numbers.
Example: Zone 1 = Fire, Zone 2 = Panic, Zones 3-8 = Burglary.
9.29.2
9.29.2
9.2
COMMERCIAL USE OF THE SC1600LCOMMERCIAL USE OF THE SC1600L
COMMERCIAL USE OF THE SC1600LCOMMERCIAL USE OF THE SC1600L
COMMERCIAL USE OF THE SC1600L
Note: Only the SC1600 Control Panel is suitable for use in
Commercial Burglary installations. Its Grade A Cabinet that it
comes standard with, complies with the UL requirements
below.
Follow the instruction below for compliance to:
Grade A Police Connected Mercantile Premises Alarm System
/Safe & Vault (UL 365)
Grade A Local Mercantile Premises Alarm System / Safe and
Vault Alarm System. (UL 609)
Digital Alarm Communicator System Units. (UL 1635)
HARDHARD
HARDHARD
HARD
WW
WW
W
ARE CONSIDERAARE CONSIDERA
ARE CONSIDERAARE CONSIDERA
ARE CONSIDERA
TIONSTIONS
TIONSTIONS
TIONS
1. Do not plug the Basler transformer into a receptacle controlled
by a switch.
2. All burglary zones must be terminated by a 2200 ohm 1/2 Watt
resistor which is included with each unit. (P/N 123-000222).
3. All fire type zones of protection must be terminated with an end-
of-line module which is sold separately. (P/N EOL2200).
4. Use only UL listed 4-wire smoke detectors and EOL relay
modules.
5. Use only UL listed bell or siren drivers and Grade A Bell
housing for commercial installations. Maximum current for the
bell output should not exceed 300mA.
Suggested bells: Wheelock MD-G10-12-R.
Suggested bell housing: Ademco model AB12.
Note: The bell in the Ademco AB12 must be removed a
replaced with the Wheelock bells to stay within the 300mA bell
rating. Some drilling may be required to mount the new bell.
The two tamper switches and the inner housing tamper of the
AB12 must be used.
6. Maximum combined current draw for Auxiliary, Fire, Keypad,
and Auxiliary status outputs (Arm, Ready, Aud. Warning, and
Courtesy) is 500mA.
7. Use a Yuasa 12 volt 18AH battery. (Yuasa (NPG18-12).
8. When using the Courtesy output, used only UL listed burglary
alarm interface modules. Suggested module: X-10 BA-284.
9. If using the keyswitch input, use only UL listed momentary
keyswitches. An SK1L keypad must be used in conjunction with
the keyswitch.
10. UL listed SC1600 Accessories:
SK1L LCD keypad - Current draw = 100mA Max.
EKP1 keypad - Current draw = 100mA Max.
EEM-8 zone expander.
11. Use only UL listed annunciators for the Audible warning
output.
12. Cut jumper JPO.
13. Use the commercial grade Enclosure (included with the SC1600).