PANEL FUNCTIONS
STEP 61 205 FUNCTION SELECT GROUP 1
Use the following chart to set the first system function group:
1 No EOL present 2 Call back security
3 Installer Privacy code 4 50 hertz AC
5 Chime Enabled 6 No Exit Annunciation
7 Latched fire bell 8 Partitioned mode
1 When this feature is selected, only closed circuit burglary zones
can be used because the panel will consider a short on the zone to
be the normal condition and a open to be alarm.
2 When this feature is selected, the following Up/Down
load sequence is performed:
a. The Computer calls the remote system.
b. The remote system acknowledges the call and hangs up.
c. The remote system then calls back the Computer (using
the third telephone number) to perform the Up/Download
operation.
3 When this feature is selected, the P1 jumper (located on the
system circuit board) is no longer able to change the Installers ac-
cess code it now changes user code #1.
4 Select this feature when the system is powered from 50Hz AC
source (i.e., European installations).
5 Select this feature to enable chime operation.
6 Select this feature to defeat the exit annunciation.
7 When this feature is selected, the access code must be used
to shut-off the fire bell.
8 Activate primary/secondary partitioning.
PARTITIONED OPERATION
The AV9000 has the capability of partitioned operation. Partitioned
operation allows two or more users to share the same control panel,
however each user will only be able to utilize and control factory se-
lected zones. There are two partitions available for the system.
NOTE: For additional information on Partitioned Operation see Sec-
tion 1.6.
STEP 62 206 FUNCTION SELECT GROUP 2
1 Auto bell test 2 No F/C kypd trouble
3 DTMF tone dial 4 European rotary dial
5 Door strike enabled 6 Disable ring back
7 Smoke reset 8 Enable kypd tamper
1 Causes a short 2-3 second bell output when system is armed.
2 Disables Failure to Communicate annunciator at keypad.
3 Select this digit to enable Tone dialing. When this function is not
programmed, the system defaults to rotary dialing.
4 Enable European rotary dialing (70 millisecond break and 30
millisecond make timing). If not programmed, the system defaults to
standard 60/40 make break rotary dialing.
5 Enables door strike output on DOB board. This feature is set as
a default from the factory.
6 Disables ring back to acknowledge a successful transmission
of a closing signal.
7 Select this digit to enable smoke reset from the keypad. To re-
set, press 1 and 3 key simultaneously. (WARNING
Keypair 1 will not report when this is selected.)
8 Select this digit to enable the tamper switch option in the
keypad. (WARNING Keypair 4 will not report when
tamper is selected)
(NOTE: The keypad tamper feature is only
available in the European version of the panel.)
STEP 63 207 EMERGENCY KEY PAIR BELL ENABLE (1-8)
If programmed, each emergency key pair can activate one or both
types of bell operation. In single bell operation, the Fire bell has prior-
ity. Use the following table to select type of operation. For silent op-
eration leave these locations blank.
Key pair Burglar Fire
1 & 3 1 5
4 & 6 2 6
7 & 9 3 7
* & # 4 8
STEP 64 208 BYPASS GROUP 1
If desired, bypassable zones can be grouped together to allow
bypassing with a minimum of keystrokes. Program the desired
zones.
209-210 NOT USED
211 RESERVED PANEL STATUS
212 RESERVED ZONE ARM STATUS
213 RESERVED ZONE ALARM MEMORY
214 NOT USED
215 RESERVED UNREPORTED ALARMS
216 VIEW HISTORY