Owner`s manual

17
FIGURE 9
35
133 ZONE REPORT DELAY TIME (x10sec) (1 - 15)
36
134 AC & LOW BATTERY REPORT DELAY (x1min) (1 - 15)
37
135 FALSE ALARM SHUTDOWN COUNT (1 - 15)
Weekdays = 1 - 7 ( Sunday = 1 - Saturday = 7 ) 136 137 138 139 140
38
136-140 TIMER REPORT [month] [weekday] [day] [hour] [min]
39
141 ASSIGNABLE RELAY OUTPUT #1 BLANK = BURG BELL 1 = Audible Warning 2 = Door Strike 3 = Strobe Light
40
142 ASSIGNABLE RELAY OUTPUT #2 BLANK = FIRE BELL 4 = Courtesy 5 = Arm/Disarm/Alarm 6 = Ready/Trouble
41
143 REPORTING ATTEMPTS
*
Factory Set ( refer to compliance section in manual)
*
42
144 ANSWER ON RING NUMBER [10]
43
145-148 INSTALLER ACCESS CODE DIGITS [7777]
44
149-152 USER 1 ACCESS CODE DIGITS [1111]
153-156 USER 2 ACCESS CODE DIGITS
157-160 USER 3 ACCESS CODE DIGITS Note:User # 8 is the Door Strike code
161-164 USER 4 ACCESS CODE DIGITS Access Codes if Door Strike is selected in 141 or 142.
165-168 USER 5 ACCESS CODE DIGITS Must be 4 Digits
169-172 USER 6 ACCESS CODE DIGITS
173-176 USER 7 ACCESS CODE DIGITS (SELECT ZONES)
177-180 USER 8 ACCESS CODE DIGITS 1 2 3 4 5 6 7 8
45
183 MISC SELECTION GRP. 3 Items 1 & 2 enable Reverse
output on Assignable Outputs. Select 1 and/or 2 for assignable relay outputs #1/#2. Select "3" for enablement of the "Defeat Lockout"
- When enabled Exit/Entry and Follower zones can be faulted at time of Arming. Select "4" to activate the "Do not Dial without Dialtone".
46
185 DELAY GRP 1 ZONES (Select E/E + Follower zones) [ 3 ]
186 DELAY GRP 2 ZONES (Select E/E + Follower zones)
47
187 ZONES TO DIAL FIRST RECEIVER
(select zones)
188 ZONES TO DIAL SECOND RECEIVER
(select zones)
189 ZONES TO DIAL THIRD RECEIVER
(select zones)
48 AUXILIARY DIAL SELECT
1 = Keypad Panics 3 = AC Loss, Low Battery, Trouble, Upload
2 = Opening/Closing, Station 5 = Test Timer 7 = Status, Bypass
190 AUXILIARY CODES TO DIAL PHONE # 1
(select event)
191 AUXILIARY CODES TO DIAL PHONE # 2
(select event)
192 AUXILIARY CODES TO DIAL PHONE # 3
(select event)
49
193 TEST CANCEL ZONE SELECTION
(select zones)
50
194 RESTORE ZONE SELECTION
(select zones)
51
195 REPORTING DELAY ZONE SELECTION
(select zones)
52
196 * BYPASSABLE ZONE SELECTION
(select zones)
53
197 AUDIBLE BURGLARY, SELECT ZONES
(select zones)
[ 2345678 ]
54
198 ENTRANCE / EXIT ZONE SELECTION
(select zones)
[ 3 ]
55
199 AUDIBLE FIRE, SELECT ZONES (24HR)
(select zones)
[ 1 ]
56
200 24 HOUR AUDIBLE ZONE SELECTION
(select zones)
57
201 SILENT PANIC, SELECT ZONES (24HR)
(select zones)
58
202 CHIME ZONE SELECTION
(select zones)
59
203 DAY/NIGHT TROUBLE ZONE SELECTION
(select zones)
60
204 TROUBLE REPORT ZONE SELECTION
(select zones)
61
205 MISC. SELECTIONS GRP 1 (select functions)
1 = No End-of-Line Resistors 3 =Installer Code Privacy 5 = Chime Enable
7 = Latched Fire Bell
2 = Call Back Security 4 = 50 Hertz A/C 6 = No Exit Enunciation 8 = Primary/Secondary Partition
206 MISC. SELECTIONS GRP 2 (SELECT FUNCTIONS) [ 6 ]
1 = Auto Bell Test 3 = TouchTone Dialing 5 = Door Strike Enable 7 = Use (1 & 3) as Smoke Reset
2 = Inhibit FC Annunciation
4 =Do Not Use
6 = Disable Ringback
8 = Enable Keypad Tamper **
62
BURG BELL FIRE BELL
1&3 4&6 7&9 *&# 1&3 4&6 7&9 *&#
12345678
207 KEYPAD PAIRS - BELL ACTIVATION
63
208 BYPASS GROUP SELECTION Zones must be in item 196
* DO NOT ALLOW FIRE ZONES TO BE BYPASSED ** This option will disable Keypair #4. For use only with tampered keypads.