Owner`s manual
13
FIGURE 6
35
133 ZONE REPORT DELAY TIME (x10sec) (1 - 15)
36
134 AC & LOW BATTERY REPORT DELAY (x1min) (1 - 15)
5
37
135 FALSE ALARM SHUTDOWN COUNT (1 - 15)
3
Weekdays = 1 - 7 ( Sunday = 1 - Saturday = 7 ) 136 137 138 139 140
38
136-140 TIMER REPORT [month] [weekday] [day] [hour] [min]
2 0
39
141 ASSIGNABLE RELAY OUTPUT #1 BLANK = BURG BELL 1 = Audible Warning 2 = Door Strike 3 = Strobe Light
40
142 ASSIGNABLE RELAY OUTPUT #2 BLANK = FIRE BELL 4 = Courtesy 5 = Arm/Disarm/Alarm 6 = Ready/Trouble
41
143 REPORTING ATTEMPTS
*
Factory Set ( refer to compliance section in manual)
*
42
144 ANSWER ON RING NUMBER
8
[10]
43
145-148 INSTALLER ACCESS CODE DIGITS
7 7 7 7
[7777]
44
149-152 USER 1 ACCESS CODE DIGITS
1 1 1 1
[1111]
153-156 USER 2 ACCESS CODE DIGITS
157-160 USER 3 ACCESS CODE DIGITS Note:User # 8 is the Door Strike code
161-164 USER 4 ACCESS CODE DIGITS Access Codes if Door Strike is selected in 141 or 142.
165-168 USER 5 ACCESS CODE DIGITS Must be 4 Digits
169-172 USER 6 ACCESS CODE DIGITS
173-176 USER 7 ACCESS CODE DIGITS (SELECT ZONES)
177-180 USER 8 ACCESS CODE DIGITS 1 2 3 4 5 6 7 8
45
183 MISC SELECTION GRP. 3 Items 1 & 2 enable Reverse
output on Assignable Outputs. Select 1 and/or 2 for assignable relay outputs #1/#2. Select "3" for enablement of the "Defeat Lockout"
- When enabled Exit/Entry and Follower zones can be faulted at time of Arming. Select "4" to activate the "Do not Dial without Dialtone".
46
185 DELAY GRP 1 ZONES (Select E/E + Follower zones)
# #
[ 3 ]
186 DELAY GRP 2 ZONES (Select E/E + Follower zones)
47
187 ZONES TO DIAL FIRST RECEIVER
(select zones)
# # # # # # # #
188 ZONES TO DIAL SECOND RECEIVER
(select zones)
# # # # # # # #
189 ZONES TO DIAL THIRD RECEIVER
(select zones)
48 AUXILIARY DIAL SELECT
1 = Keypad Panics 3 = AC Loss, Low Battery, Trouble, Upload
2 = Opening/Closing, Station 5 = Test Timer 7 = Status, Bypass
190 AUXILIARY CODES TO DIAL PHONE # 1
(select event)
# # #
191 AUXILIARY CODES TO DIAL PHONE # 2
(select event)
# # #
192 AUXILIARY CODES TO DIAL PHONE # 3
(select event)
# #
49
193 TEST CANCEL ZONE SELECTION
(select zones)
# #
50
194 RESTORE ZONE SELECTION
(select zones)
# # #
51
195 REPORTING DELAY ZONE SELECTION
(select zones)
52
196 * BYPASSABLE ZONE SELECTION
(select zones)
# # # # #
53
197 AUDIBLE BURGLARY, SELECT ZONES
(select zones)
# # # # # #
[ 2345678 ]
54
198 ENTRANCE / EXIT ZONE SELECTION
(select zones)
#
[ 3 ]
55
199 AUDIBLE FIRE, SELECT ZONES (24HR)
(select zones)
#
[ 1 ]
56
200 24 HOUR AUDIBLE ZONE SELECTION
(select zones)
57
201 SILENT PANIC, SELECT ZONES (24HR)
(select zones)
#
58
202 CHIME ZONE SELECTION
(select zones)
#
59
203 DAY/NIGHT TROUBLE ZONE SELECTION
(select zones)
60
204 TROUBLE REPORT ZONE SELECTION
(select zones)
#
61
205 MISC. SELECTIONS GRP 1 (select functions)
1 = No End-of-Line Resistors 3 =Installer Code Privacy 5 = Chime Enable
7 = Latched Fire Bell
2 = Call Back Security 4 = 50 Hertz A/C 6 = No Exit Enunciation 8 = Primary/Secondary Partition
206 MISC. SELECTIONS GRP 2 (SELECT FUNCTIONS)
# #
[ 6 ]
1 = Auto Bell Test 3 = TouchTone Dialing 5 = Door Strike Enable 7 = Use (1 & 3) as Smoke Reset
2 = Inhibit FC Annunciation
4 =Do Not Use
6 = Disable Ringback
8 = Enable Keypad Tamper **
62
BURG BELL FIRE BELL
1&3 4&6 7&9 *&# 1&3 4&6 7&9 *&#
12345678
207 KEYPAD PAIRS - BELL ACTIVATION
# #
63
208 BYPASS GROUP SELECTION Zones must be in item 196
# # #
* DO NOT ALLOW FIRE ZONES TO BE BYPASSED ** This option will disable Keypair #4. For use only with tampered keypads.