Specifications
4-14 OPERATION CHAPTER 4
DT-203X, DT-105X and DT-110X display series
0Ah or 0Ch characters forces a change of line on multinear displays. It allows all the
lines from a single dislay to be sent in just one data block.
Example: Display of 8 lines. Address 2
Sent code: 02h 10h 04h 01h 00h 04h 08h 31h 32h 33h 34h 0Ah
41h 42h 43h CRC
Modify line 4 to: 1234, modify line 5 to: ABC.
The rest of lines are not modified.
Code 00h is transparent and therefore any character will not be displayed
00h 22h Brightness adjust. To adjust the display brightness. Valid range is from 1 to 8 in
ASCII code.
Example: 00h 22h 38h Adjust highest brightness.
ONLY WITH HUMIDITY AND TEMPERATURE OPTION
00h 1Eh: displaying temperature in Celsius. It needs 6 characters.
00h 1Fh: displaying temperature in Farenhait. It needs 6 characters.
00h 21h: displaying relative humidity. It needs 2 characters.
4.4.2.9.2. Control by code.
Message without variables.
The message number is in the two first bytes of the data block.
Data block. Minimum 4 bytes.
B1
B2
B3
B4
B1: MSB of message number. In hexadecimal.
B2: LSB of message number. In hexadecimal.
B3: Always 0.
B4: Always 0.