SOLUTION DISPENSING TUBE
The solution dispensing tube has a flushing
connection built in. The flushing connection is the
tee fitting next to the solution control valve. This
allows a garden hose to be threaded into the
dispensing system to flush the system. Flush the
system after every 50 hours of operation.
SRS METERING SOLUTION PUMP
A bellows pump meters cleaning solution into the
recycling solution at rates of one-quarter, one-half
and one percent. The cleaning solution is
introduced to the recycling solution at a point just
before the spray nozzle. Clean the metering pump
daily when cleaning the solution tank.
TROUBLESHOOTING
Low Flow
1. Poppet valves dirty, dried cleaning solution
residue on valves.
2. Restriction in cleaning solution lines.
3. Air leak at pump intake.
4. Defective wiring or motor.
Motor Fails to Turn On
1. Loose wiring connection.
2. Defective motor .
Motor Operates, But No Pump Discharge
1. Damaged bellows.
2. Restriction in cleaning solution lines.
3. Air leak in intake line.
4. Unprimed pump.
a. Remove pump inlet hose.
b. Fill pump chamber with approximately
one ounce SRS solution.
c. Reinstall pump inlet hose.
d. Pump should start metering tank
solution after 3 to 4 minutes run time.