Instruction manual
16
Operation
Motor Torque Limit Menu
In this screen the CLM-3 motor torque can be adjusted in
four steps. The adjustment is only available if a motor
with high power drive is detected (UMC-3A, ARRIFLEX
416 PLUS (HS) or ALEXA Plus/Studio)
high value (4) - high torque - low value(1) - low torque
Note:
Controlling the ALEXA Plus/Studio, torque adjustment is
possible
at the ALEXA Plus/Studio only.
Please select the required torque level carefully:
Torque Adjustment Instructions
Higher torque levels should be used for rough-running lenses.
Note:
Take care to re-calibrate the CLM-3 motor after re-attachment
of the motor and after each lens change!
Ignoring this procedure can lead to severe lens damage.
Lower torque levels should be used for smooth-running lenses.
Note:
If the torque level is not adequate to lens properties or
operation temperature, the electronic torque limitation may
cause a high-frequency noise.
Use a higher torque level to reduce this effect.