Instruction manual
28
1x / INT switch
SF ON / OFF switch
RDY LED
Singleframe Handcontrol
7.1 Switching on
Singleframe Operation
Before switching on singleframe operation,
ensure that the singleframe guide is correctly
installed, that the plate on the Integrated Capping
Shutter can be moved easily, that the Singleframe
Film Recognition module is attached, that the
cover for the openings in the film gate is correctly
attached and that the eyepiece is closed (see
chapter Preparing the ARRIFLEX 435 for Single-
frame Shots).
• Turn the 1x / INT ➪ photo switch to 1x.
• Turn the SF switch to ON ➪ photo;
the RDY LED ➪ photo illuminates red briefly (initialising),
then green.
Note: When singleframe operation is switched on, the
Integrated Capping Shutter is controlled automa-
tically by the Singleframe Hand Control and can
therefore not be operated manually.