User's Manual

33
Side view on the opened OM2000A+
HV Transformer AC Selector
Remove the upper lid first. On the right side of the PA, next to the HV transformer there are two
PCBs mounted. On the left upper side of the front (Switch-ON) board connector J6 is located.
Use flat screwdriver or finger and press carefully
the white stick to release contact and move
upper end of the white jumper to the proper
position, if necessary.
Jumper must be connected between bottom
contact and one of remaining contacts. AC
voltage is marked next to every contact.
AC selector range can be changed in the production according to the specific conditions in individual
countries.
Type of supported TCVR and working
frequency are visible on the display.
AUTO LED is ON.