User's Manual
20
UPGRADE touch button can be used
ONLY in the case if EEPROM or
firmware files (or both) will be
upgraded. In such a case ask dealer or
manufacturer for the exact procedure.
5.3. Preparing for operation
In STBY the amplifier is in bypass-mode and your transceiver is directly connected to
the antenna. Maximum allowed power in bypass mode is 200 Watts! Passing RF
power is displayed if PA is in standby mode.
To turn PA ON press ON/OFF button on the front panel (black one) and hold it abt. 1 second. PA
will start tube heating. It will take 180 seconds. Turning PA ON is possible ONLY from the home
screen! If you have other display active, press EXIT more times to go back to the home screen.
Time to go is visible on the display.
Wait until heating finish.
Type of supported TCVR and
working
frequency are visible on the
display.
AUTO LED is ON.
Type of supported TCVR and
working
frequency are visible on the
display.
AUTO LED is ON.