Band inclusion. The amplifier can be shipped with 10 and 12-meter capability disabled as required by
the Federal Communications Commission (FCC), for United States users. Contact your dealer about
enabling those bands.
1-5. Safety Considerations, Explicit Definitions
The ACOM1011 HF Linear Amplifier is a Safety Class I unit. The grounding lead (yellow with 2 green
stripes) of the power cable and the ground stud on the rear panel of the amplifier (marked GND) must be
connected to the station's grounding system for safe operation. The amplifier is designed to meet
international safety standards and complies with CE safety and electromagnetic compatibility requirements,
as well as FCC regulations. This operating manual contains an assortment of precautions and warnings
that MUST BE FOLLOWED BY THE USER to ensure safe operation of the amplifier.
The safety definitions below apply to this operating manual:
A
WARNING
is associated with a procedure that, if not properly performed, could result in a fire hazard or
electric shock, with resulting injury or death to the user.
A
CAUTION
is associated with a procedure that, if not properly performed, could result in damage to the
amplifier or other equipment.
A NOTE is associated with a procedure that, if not properly performed, could result in inconvenience or
physical injury to the user.
WARNING HIGH VOLTAGE!
The amplifier works with voltages up to 3000 V dc, which are potentially LETHAL! You must unplug the
amplifier from the line (mains) wall outlet and WAIT AT LEAST 30 minutes before removing the cover of the
amplifier. Do not touch any part inside while the amplifier is open because dangerous voltages may remain
present.
WARNING HIGH VOLTAGE!
NEVER ALLOW ANYONE, ESPECIALLY CHILDREN, to push anything into the case holes or to otherwise
touch the amplifier or its connecting cables. There is grave danger of fatal electrical shock. NEVER TOUCH
AN ANTENNA during transmission as this may result in an electric shock or burns. NEVER EXPOSE the
amplifier to rain, snow or any liquids. AVOID placing the amplifier in excessively dusty environments. DO
NOT OBSTRUCT AIR INTAKE (bottom) or EXHAUST (top cover) areas of the amplifier. Keep a minimum
distance of 50cm (20 inches) clear of the air exhaust opening.
WARNING
Do not undertake or perform any repair or adjustment of your amplifier yourself, including any attempt to
change hardware or firmware. Doing so creates a potentially fatal shock hazard and may damage the
amplifier or equipment connected to it. ACOM is not responsible for any such personal injury or equipment
damage, whether caused by accident or as a result of good faith efforts at repair or adjustment.
CAUTION
To avoid damage to the amplifier not covered by ACOM’s warranty, the user is expected to read and comply
with the installation instructions contained in Section 2 of this operating manual. If there are any doubts or
questions concerning installation, operation or safety of the amplifier, the user should contact ACOM.