User Manual

Exhibit 6 page 16 of 16
d) LED bar-graphs for forward peak power and reflected power.
e) Service visualization of grid 1 DC current, grid 2 DC voltage, and plate DC current.
f) Tubes: two 4CX250B (7203) ceramic-metal tetrodes with a total plate dissipation of 500W (forced air
cooling), grid-driven.
6-3. Storage and Shipment
CAUTION
Should it be necessary to ship the amplifier, use the original packing as described below.
Switch off the amplifier, pull the line (mains) plug out of the outlet, disconnect all cables from the rear panel
of the amplifier (remove the ground connection the last), and then pack the amplifier in its original carton.
a) Acceptable storage environment: The amplifier may be kept packed in a dry, ventilated and unheated
location (with no chemically active substances such as acids or alkalis) within the following environment
ranges:
- Temperature range: -40 to +70 degrees Celsius
- Humidity: up to 75% @ +35 degrees Celsius.
b) Shipping Size and Weight: WxDxH: 535x445x270mm, 21kg (21x17.5x10.6 inches, 46.3Lbs).
c) All types of transportation may be used, including storage in an aircraft baggage compartment at up to
12000 meters (40,000 feet) above sea level.