User Manual

Page 27 of 34
Fig. 5-6 Menu : RESTORE DEFAULT SETTINGS
In order to confirm the selected action the operator must press the ACTION - left (YES) button once more. After
its implementation the control returns to the MENU SELECTION screen - Fig. 5. If instead the ACTION - right
(NO) button is pressed, the selection “NO” is selected again, and the control does not leave the current
position. At pressing the EXIT button in this position, the control leaves this menu without changing anything
and returns in the previous window (the MENU SELECTION screen Fig. 5). At repeated pressing the EXIT
button, it returns to the basic screen of the amplifier (Fig. 3-2).
6. REMOTE MONITORING AND CONTROL
6-1. General information
Remote monitoring and control can be done with a computer connected to the RS232 interface of the amplifier.
It can control and monitor the main amplifier functions as follows:
- activation (turn on) of the main power supply from the Low Energy (waiting) mode through
simultaneous activation of the RTS and the DTR signals;
- deactivation (turn off) of the main power supply and return to the Low Energy (waiting) mode using a
serial command OFF;
- change of the Operate / Stand-by mode; this and next serial commands are accessible only when the
main power supply is running;
- change of the receive / transmit (RX/TX) mode;
- change of the operating frequency (BAND);
- upgrade of the firmware;
- change, activation, and deactivation of some options, such as AUTO OPERATE, OPERATE
ACCESS, the temperature scale unit ºC/ºF;
- reading the FAULTS LOG, and others.