Operating instructions
VU METERS
1
3
5
7
9
2
4
6
8
10
AUX RIGHT
AUX LEFT
GROUND
PROGRAM LEFT
PROGRAM RIGHT
AUX RIGHT
AUX LEFT
GROUND
PROGRAM LEFT
PROGRAM RIGHT
4-6e) VU Meter Cable -
This cable connects the Output Board and the VU meters.
4-6f) Monitor Select Switch & Cable
- This cable connects the Monitor Select switch to the Output
Board.
4-6g) Monitor Volume Pot & Cable
- This cable connects the Monitor Volume pot to the Output Board.
1
3
5
7
9
2
4
6
8
10
SW1 = EXT 1
SW2 = EXT 2
SW3 = PGM
SW4 = AUD
SW5 = MONO
nc
nc
nc
GND
GND
1
3
5
7
9
2
4
6
8
10
SW1 = EXT 1
SW2 = EXT 2
SW3 = PGM
SW4 = MONO
SW5 = MIX (-)
nc
nc
nc
GND
GND
5 CHANNEL CONSOLE
*
10 & 15 CHANNEL CONSOLES
OFF SW5 SW4 SW3 SW2 SW1
1
*NOTE: cable harness is the same on all console models. The functional difference is in the Output board.
1
3
5
7
9
2
4
6
8
10
nc
nc
+VDC
CTRL
-.7VDC
nc
nc
+VDC
CTRL
-.7VDC
1
FULL ON
FULL OFF
10k½ POT
LINEAR TAPER
ELECTRONIC DESCRIPTION
Arrakis Systems, inc. --- 6604 Powell st., Loveland, CO 80538 --- 970-461-0730 --- www.arrakis-systems.com
CONSOLE ASSEMBLIES
4-6)
4.14