Operating instructions
JUMPER CONNECTIONS FOR VARIOUS AC SUPPLY VOLTAGES
AC
POWER
PLUG
EXAMPLE- Transformer jumpers set for 120VAC operation
AC line input voltage conversion requires reconfiguration of the power supply's AC transformer:
4-1d) OPEN FRAME POWER SUPPLY
The 1200 series console uses a bipolar (positive and negative DC) “International Series” open frame
supply built for Arrakis by Power One Inc.
The supply is adjustable from roughly ±10 to ±17 VDC.
Protection is provided in the form of current limiting-foldback. Load regulation is
± .05% for 50% load
change. Ripple is 5mv peak to peak maximum. Transient response is 50ms to a 50% load change.
SAFETY SPECIFICATIONS
Power One literature shows they meet or exceed safety requirements for IEC380, IEC435, VDE 0730
Part 2, VDE 0804, ECMA-47,
CEE 10 Part 2P, UL1012, CSA22.2 No. 143, CSA 22.2 No. 154.
Specifically, leakage current is less than 5 milliamps. Dielectric withstand
is 3750VAC input to chassis
and input to output with 300 VDC output to chassis.
4-1e) 110VAC to 220VAC CONVERSION
The power supply can be operated on a variety of AC line voltages. The supply is set up for 120VAC
operation as shipped from operation as
shipped from the factory unless otherwise requested. The supply will run on
frequencies from 47 to 63 Hz
and voltage variations of +10% to -13%.
Conversion to different
line voltages is accomplished by moving jumpers on the power supply.
FOR 110VAC OPERATION - APPLY AC TO PINS1 AND 5
Jumper pins1 to 3 and pins 2 to 4
FOR 120VAC OPERATION - APPLY AC TO PINS1 AND 4
Jumper pins1 to 3 and pins2 to 4
FOR 220VAC OPERATION - APPLY AC TO PINS1 AND 5
Jumper pin 2 to pin 3
FOR 230VAC OPERATION - APPLY AC TO PINS 1 AND 4
Jumper pin 2 to pin 3