Operating instructions
NOTE -
WARNING!!!
ALWAYS unplug the power supply before opening the chassis.
Potentially deadly AC line voltage is present within the power supply cabinet.
4-1b) FUSE
The power supply cabinet is equipped with an INTERNAL AC fuse. If the fuse blows, then
replace it with a 2 AMP SLO-BLO FUSE.
Use no substitutions!
4-1a) 1200 POWER SUPPLY - GENERAL DESCRIPTION
The 1200‘s power supply (Arrakis model number TPS2) contains one 3 amp bipolar open frame
power supply.
See Section 3-1d for cabinet dimensions.
TPS2 TOP VIEW
DC POWER CONNECTOR
1) (-) 12.6VDC OUT (BLU)
2) GROUND (GRN)
3) (+) 12.6VDC OUT (ORN)
4) NC
5) NC
6) NC
7) (+) 12.6VDC OUT (BLU)
8) GROUND (GRN)
9) (-) 12.6VDC OUT (ORN)
7 4 1
8 5 2
9 6 3
FUSE HOLDER
3.0 AMP
BIPOLAR
SUPPLY
4-1c) GROUNDING
THE POWER SUPPLY CABINET MUST BE GROUNDED AT ALL TIMES!!!
ground is totally.
Grounding is accomplished by
plugging the power supply into a grounded three prong AC outlet.
The power supply‘s electronic floating in respect to the cabinet‘s chassis ground
(AC
ground), therefore there is no advantage to removing the third prong on the AC power cord to
try to alleviate a ground loop. If the AC ground is defeated
on the power cord or AC outlet then
the power supply cabinet MUST be grounded through other means. Failure to do so will result in a
safety hazard.
ELECTRONIC DESCRIPTION
Arrakis Systems, inc. --- 6604 Powell st., Loveland, CO 80538 --- 970-461-0730 --- www.arrakis-systems.com
POWER SUPPLY DESCRIPTION
4-1)
4.1