Operating instructions

Arrakis Systems, inc. --- 6604 Powell st., Loveland, CO 80538 --- 970-461-0730 --- www.arrakis-systems.com
INSTALLATION PROCEDURES
UNPACKING & PHYSICAL INSTALLATION
3-1)
3.1
3-1a) UNPACKING
The 1200 Series console is shipped in a specially designed cardboard shipping container with foam
fill. This box contains the console
but not the power supply or installation supplies. The power supply
is shipped in a seperate cardboard carton along with the manual, spare
parts kit and installation kit.
Check all cartons and equipment for shipping damage immediately upon receipt. If any damage is
found,
contact Arrakis Systems immediately at (970) 461-0730. Do NOT throw away any packaging
material until after console installation
is complete and satisfactory.
3-1b) TABLETOP INSTALLATION
The 1200 Series console, if tabletop mounted, does not require a hole for the console itself. However,
holes must be provided for cable
routing. See Section 3-1g for locations and dimensions of cutouts.
There must be sufficient clearance above the console (>13") to accomodate the upward and forward
hinging top panel. Refer to
the diagram on the next page for console dimensions and clearances.
In general, the console should be installed in a tabletop 24"-36" deep with at least 3" to 4" of clearance
on either side, 13" clearance above
and 6" clearance in front.
The console can be screwed down to the tabletop if deemed necessary. Holes are provided through
the bottom of the console
behind the motherboards.
3-1c) THRU-TABLE INSTALLATION
While the 1200 console does not require a through the table mounting system, it may be mounted
through the table for a more trim
line look. To do this, a hole is cut through the table surface to the
dimensions described in Section 3-1h such that the console drops
down to the edge of the wood
side and front trim. Over hangs on all four sides of the console make a through the table mount an
easy and attractive option for the console.
3-1d) POWER SUPPLY INSTALLATION
The consoleā€˜s power supply (Arrakis model number TPS2) is cabinet mount (not rack mount). Be
certain to provide enough
ventilation to insure adequate power supply cooling.
6 1/4"
9 1/4"
12"
10"
front
view
side view
TPS2 POWER SUPPLY DIMENSIONS
Cable lengths
a) Power supply AC power cable-
6 feet
b) Power Supply DC power cable-
10 feet
c) Console DC power Cable-
8 feet