Specifications
Sentinel 6 Rack
For outstanding power protection and
communication SENTINEL 6 RACK is
the best solution for sensitive
and “mission-critical” applications.
The SENTINEL 6 RACK series
comprises the 700-1000-1500-2200-
3000VA models and uses double
conversion technology (VFI). The load is
powered continuously by the inverter
with an EMI filtered, stabilised and
regulated sinewave supply.
The input and output EMI filters
considerably increase the immunity of the
load to mains disturbances and surges,
even on bypass. The UPS can power the
load for long periods (using battery
extension packs) or provide sufficient
runtime to allow shut-down of the
protected computer systems using the
Watch&Save 3000 software, supplied as
standard.
SENTINEL 6 RACK POWER
models are supplied with a larger
internal charger and with their
matching external battery
extension packs can achieve long
back up times.
ADVANCED COMMUNICATION
• Advanced, multi-platform communication
for all operating systems and network
environments: Watch&Save 3000
monitoring and shut-down software
included, for Windows 2008, XP, Vista
and 2003; Mac OS X, Linux, Novell and
most popular Unix operating systems.
• The UPS is supplied with a
communication cable for Plug and Play
PC connection
• UPS tools configuration software
• Emergency Power Off (EPO) contact
• RS232 serial port
• Slot-in SNMP network adapter card.
APPLICATIONS
• Local Area Networks (LAN)
• Data Centers
• Servers
• Industrial PLCs
• Cash registers
• Emergency devices (lights/alarms)
• Telecommunication devices
2-YEAR WARRANTY
40
OPTIONS
Extended runtime solutions
(except 700VA)
External manual bypass (wdh) mm/kg
• Rack version
438x360x2U / 6,8
• Box version
300x115x180 / 3,3
CHARACTERISTICS
• Reliable, stabilised, filtered voltage
double on-line conversion technology
(VFI according to EN62040-3
specifications) with filters for the
suppression of atmospheric
disturbances
• High overload capability (up to 150%)
• Auto restart when mains power returns
(programmable)
• Power factor correction with sinusoidal
input to ensure a low impact on the
mains supply (UPS input power factor,
close to 1)
• Wide input voltage range (110-300Vac)
to reduce battery usage
• Integrated protection for PC networks
and telephone line/modem
connections RJ45-RJ11
• Option to extend the back up time to
several hours
• Programming of operating functions via
software
• Timer for scheduled shut-down
(software programmable)
• High level reliability of the batteries
(automatic and manual test)
• High level reliability of the UPS (full
microprocessor control)
• Breaker based input protection