Datasheet

Section
3
Page
1.3
Date
10.02
OJ Microline
®
range . Type OCC2
4-Event
Clock Thermostat
Elegant European design
can be mounted in
combination with various
types of light switches
4-event clock thermostat type OCC2
■ Recommended for control of heating systems for
heating comfort with minimum power consumption.
■ Electronic on/off control max. 3600W, 16A, of
underfloor heating and electrical heating etc.
■ Built-in interrupter.
■ Back-lit display.
■ Built-in clock function with display for automatic
comfort and setback temperature.
■ Flush mounting or wall mounting.
■ Monitoring of energy consumption.
■ Inclined display for better read-out.
PRODUCT PROGRAMME
THERMOSTAT FUNCTIONS
Thermostat control:
Type OCC2 is an electronic on/off thermostat for control
of temperature by means of a sensor either placed
externally or built into the thermostat. The heat output is
switched on and off with a difference of only 0.4˚K.
Housing IP 21:
Can be mounted in bathrooms and other humid rooms.
BUILT-IN CLOCK FUNCTION
OCC2 is with built-in 4-events program for automatic
comfort and setback temperature.
Factory-set of events:
The OCC2 types with floor sensor are delivered with factory-
set programs as follows:
Type Product
OCC2-1991H1 Clock thermostat incl. floor sensor 3 m
OCC2-1999H1 Clock thermostat with built-in room sensor
Accessories
ETF-944/99-H Remote room sensor for surface wall mounting
Used together with OCC2-1991H1
OTN-VH Baseplate for surface wall mounting
Day 1-5
Event Time Temperature
1 06:00-08:00 Comfort 25˚C
2 08:00-16:00 Setback 20˚C
3 16:00-22:30 Comfort 27˚C
4 22:30-06:00 Setback 20˚C
Day 6-7
Event Time Temperature
1 08:00-23:00 Comfort 27˚C
4 23:00-08:00 Setback 20˚C
Individual programming of events:
The factory-set periods and/or temperatures can be deleted
or changed according to requirement.
Furthermore, the following programs can be selected:
- 4 events 6 days and 2 events day 7
- 4 events per day
OCC2 is with adaptive function meaning the thermostat
calculates when the heating has to be switched on to
make sure that the comfort temperature is obtained at the
required time.
Comfort mode:
The temperature can be temporarily changed for a single event.
The comfort mode temperature is reset at the next event, and
the thermostat will return to the scheduled event program.