MAINTENANCE
NORMAL MAINTENANCE
WARNING: PRIORTO ANY OF THE FOLLOWING MAINTENANCE PROCEDURESSHUT OFF
ALL ELECTRICALPOWERTO THE UNIT. FAILTURETO DOSOCOULDCAUSE PERSONALIN-
JURY.
Periodic inspectionand maintenancenormallyconsistsof changing or cleaningfilters and (under someconditions)
cleaning the coils.
FILTER- supplied. Inspectoncea month.Replacedisposable,or clean permanenttypeas necessary. DONOTreplace
permanenttypewith disposable.
MOTORS- indoorand outdoortan motors arepermanentlylubricatedand requirenomaintenance.
OUTDOORCOIL- Foreignmaterial shouldnot beallowedtoaccumulateonthe outdoorcoilsurfaceor other parts inthe
air circuit. Cleaningshould beas oftenas necessaryto keepthe coil clean.Usea brush,vacuum cleanerattachment,
or other suitable means. If wateris used to cleanthecoil, be sure power to the unitis shutoff prior to cleaning.
NOTE: CARESHOULDBE USEDWHENCLEANINGTHE COILSSOTHATTHE COILFINS ARENOTDAMAGED.
OUTDOORBASEDRAIN- Foreignmaterial should notbe allowedto clogthe drain hole.Inspect andclear'drain open-
ingprior to heatingseason.