Troubleshooting guide

7
Air Gap
Figure 7-1 HC-6100/6300/6500/6700
Table 7-1. Recommended Branch Circuits
Rating Amp 1-12 13-15 16-20 21-24 25-32 33-40 41-48 49-64 68-80 81-100 101-120 121-140 141-60
Wire
(AWG)
14 12 10 10 8 8 6 4 3 1 0 0 0
(mm2)
3 4 6 6 10 10 16 25 35 50 50 70 95
Circuit Breaker
15 20 25 30 40 50 60 80 100 125 150 175 200
Table 7-2. Steam Capacities and Rating Amperages
Volts
(Vac)
HC6100/HC6100DI HC6300/HC6300DI
3 KW Unit 9 KW Unit 15 KW Unit 18 KW Unit 30 KW Unit
Nominal
Amperage
Rating
Steam
Output
kg/hr
(lb/hr)
Nominal
Amperage Rating
Steam
Output
kg/hr
(lb/hr)
Nominal
Amperage
Rating
Steam
Output
kg/hr
(lb/hr)
Nominal
Amperage
Rating
Steam
Output
kg/hr
(lb/hr)
Nominal
Amperage
Rating
Steam
Output
kg/hr
(lb/hr)
Phase Phase
Three
Phase
Three
Phase
Three
Phase
Single Three Single Three
208 13.3 7.7 3.8 (8.3) 39 23 11 (24) 37 18 (40) 46 22 (48) 74 36 (80)
240 12.9 7.5
4.1 (9)
38 22
12 (27)
36
20 (45)
44
25 (54)
72
41 (90)
200 - 4.7 - 14 23 28 46
480 - 3.8 - 11 18 22 36
600 - 3 - 9 15 18 30
Table 7-3. Steam Capacities and Rating Amperages
Volts
(Vac)
HC6500/6500DI
30 KW Unit 33.5 KW Unit 40 KW Unit 48 KW Unit 45 KW Unit
Nominal
Amperage
Rating Three
Phase
Steam
Output
kg/hr
(lb/hr)
Nominal
Amperage
Rating
Three Phase
Steam
Output
kg/hr
(lb/hr)
Nominal
Amperage
Rating
Three Phase
Steam
Output
kg/hr
(lb/hr)
Nominal
Amperage
Rating
Three Phase
Steam
Output
kg/hr
(lb/hr)
Nominal
Amperage
Rating
Three Phase
Steam
Output
kg/hr
(lb/hr)
208 84 41 (90) - - - - - - 125 61 (135)
240 - - - - 96 54 (120) - - - -
400 - - 51 45 (100) - - 73
65 (144)
- -
480 - - - - - 58 - -
600 - - - - - 47 - -
Table 7-4. Steam Capacities and Rating Amperages
Volts
(Vac)
HC6500/6500DI HC6700/HC6700DI
50.3 KW Unit 60 KW Unit 72 KW Unit 96 KW Unit
Nominal
Amperage
Rating
Three Phase
Steam
Output
kg/hr
(lb/hr)
Nominal
Amperage
Rating Three
Phase
Steam
Output
kg/hr
(lb/hr)
Nominal
Amperage
Rating
Three Phase
Steam
Output
kg/hr
(lb/hr)
Nominal
Amperage
Rating
Three Phase
Steam
Output
kg/hr
(lb/hr)
240/220 - - 144 82 (180) - - - -
400/380 77 30 (68) - - 110
98 (216)
145
130 (288)480 - - - - 87 116
600 - - - - 70 93
Drainage
Connect HC-6000 drain to suitable waste drainage
system. HC-6000 drain water may be as hot as 70°C
(158°F). Use clear drain hose provided and 25 mm (1”)
copper pipe pitched away from unit at 25 mm (1”)
inch per foot. An air gap to prevent back flow is required.
See Figure 7-1.