Replacement Parts

Table Of Contents
DESIGN ENVELOPE 4300/4380 PUMP-IN-A-BOX
VERTICAL IN-LINE PUMPS
|
SUBMITTAL
49
|
HYDRONIC SOLUTIONS CATALOG
Job:
Representative:
Engineer:
Contractor:
Order no: Date:
Submitted by: Date:
Approved by: Date:
mechanical seal design data
35
6
9
10
15
25
35
45
70
90
140
2
3
4
5
7
10
15
20
30
40
40 50 70 90 100 140 180 220 280 350 450 600
2 3 4 5 7 9 10 15 20 25 4030
flow - usgpm
flow - L/s
head- feet
head- metres
Design Envelope
4380 PiB
1 1506-003.0
2 1508-001.5
3 0206-001.5
4 0208-003.0
5 0208-005.0
6 0306-001.5
7 0308-003.0
8 0308-005.0
9 0310-007.5
1 0406-003.0
Design Envelope
4300 PiB
1 0308-015.0
1 0406-010.0
3
1
4
5
1
2
8
9
1
1
6
7
performance curve
technical data
Maximum working pressure: 175 psi (12 bar)
Maximum working temperature: 250°f (121°c )
materials of construction
Construction: bf with ansi 125 flanged connection
Casing (volute): Cast iron (a48-30)
Casing gasket: Confined Non-Asbestos Fiber
Flush line: Braided Stainless Steel
Impeller: Bronze
Shaft sleeve (4380): Bronze
Pump shaft (4300): ss astm a276 Type 416
drive data
Sensorless control: Included
bms protocol: BACnet ms/tp
Enclosure: ul type 12
Fused disconnect switch: No
Control orientation: l1
Communication port: rs 485
emi/rfi control: Integrated filter designed to meet en61800-3
Harmonic suppression: Integrated dc link reactors**
Cooling: Fan-cooled through back channel
Ambient temperature: -10°c to +45°c upto 1000 meters
elevation (14°f to 113°f upto 3280ft)
Analog inputs: Two, current or voltage
Analog outputs: One, current
Digital inputs: Four programmable
Digital outputs: Two programmable
motor design data
Frequency: 60 hz
Voltage: 208-230
460 v 575 v
Enclosure: tefc
Eciency: nema premium 12.12
Seal type:
Inside single-spring (4380)
Outside balanced (4300)
Secondary seal:
epdm (4380)
viton (4300)
Rotating face: Resin bonded carbon
Stationary seat: Silicon-carbide
Springs: Stainless steel
Rotating hardware: Stainless steel
Pump equipped with casing drain plug and ¼" npt suction and
discharge gauge ports
* If minimum maintained system pressure is not known, default is
40% of design head.
** The ivs 102 control is a low harmonic control with a built-in dc link
reactor equivalent in performance to a 5% ac line reactor. This does
not guarantee performance to any system wide harmonic specifi-
cation or the costs to meet a system wide specification. If supplied
with the system electrical details, Armstrong will run a computer
simulation of the system wide harmonics. If system harmonic
levels are exceeded, Armstrong can also recommend additional
harmonic mitigation and the cost for such mitigation.