Replacement Parts
Table Of Contents
- commercial & residential pumps
- Design Envelope Compass Circulators
- Astro 2 Circulators
- Astro 2 Hot Water Recirculation Systems
- Astro 2 24-hour timer
- Aquastat controls
- Astro Express 2 Hot Water Recirculation
- S&H 3-Piece Circulators
- 1050 & 1060 3-Piece Circulators
- E.2 Circulators
- E.2 Circulator Spool Pieces
- 4270 & 4270 Stock Motor Mounted Pumps
- 4360 Pump-in-a-Box
- 4380 Pump-in-a-Box
- Design Envelope 4300/4380 Pump-in-a-Box
- hydronic specialties
- circuit balancing valves (cbv)
- replacement parts
- parts look up
- competition circulator cross reference
- technical data
- Pump Formulas
- Pressures & Altitudes
- Freezing & Boiling Points
- Ethylene Glycol Properties
- Propylene Glycol Properties
- Water Properties
- Useful System Curve Formulas
- Pipe Maximum Pressures
- Hydraulic Resistance
- Pipe Information
- Pipe Fittings & Valves Friction Loss
- Water Flow Calculator
- Unit Conversions
- Typical Symbols
- Product Solution Outlines/Brochures
TECHNICAL DATA
203
|
HYDRONIC SOLUTIONS CATALOG
4 inch
type k tubing type l tubing type m tubing pipe *
3.857" inside diameter
.134" wall thickness
3.905" inside diameter
.110" wall thickness
3.935" inside diameter
.095" wall thickness
4.000" inside diameter
.250" wall thickness
flow
(usgpm)
velocity
(ft./sec.)
head loss
(ft./100ft.)
velocity
(ft./sec.)
head loss
(ft./100ft.)
velocity
(ft./sec.)
head loss
(ft./100ft.)
velocity
(ft./sec.)
head loss
(ft./100ft.)
100 2.74 0.72 2.68 0.68 2.64 0.65 2.55 0.60
110 3.02 0.85 2.94 0.80 2.90 0.77 2.81 0.71
120 329 0.99 3.21 0.94 3.16 0.90 3.06 0.83
130 3.57 1.15 3.48 1.08 3.42 1.04 3.31 0.96
140 3.84 1.31 3.74 1.23 3.69 1.19 3.57 1.10
150 4.11 1.48 4.01 1.40 395 1.35 3.83 1.25
160 4.39 1.67 4.28 1.57 4.21 1.51 4.08 1.39
170 4.66 1.86 4.55 1.75 4.48 1.69 4.33 1.56
180 4.94 2.06 4.81 1.94 4.74 1.87 4.58 1.73
190 521 2.27 5.08 2.14 5.00 2.06 4.84 1.91
200 5.49 2.49 5.35 2.35 5.27 2.26 5.10 2.09
220 6.04 2.96 589 2.79 5.80 2.68 5.61 2.48
240 6.59 3.46 6.42 3.26 6.32 3.14 6.12 2.90
260 7.14 4.00 695 3.77 6.85 3.63 6.63 3.36
280 7.69 4.57 7.49 4.31 7.38 4.15 7.14 3.84
300 8.24 5.18 8.02 4.88 7.90 4.70 7.65 4.35
350 960 6.85 9.36 6.46 9.22 6.22 8.92 5.75
400 11.00 8.74 10.70 8.23 10.50 7.93 10.20 7.33
450 12.40 10.83 12.00 10.20 11.90 9.83 11.50 9.08
500 13.70 13.12 13.40 12.36 13.20 11.91 12.80 11.00
550 15.1 15.61 14.70 14.71 14.50 14.17 14.10 13.09
600 16.5 18.31 16.00 17.24 15.80 16.61 15.30 15.35
650 17.9 21.19 17.40 19.96 17.10 19.23 16.60 17.77
700 19.2 24.28 18.70 22.86 18.40 22.03 17.90 20.35
750 20.6 27.55 20.10 25.95 19.80 25.00 19.10 23.09
800 22.0 31.01 21.40 29.21 21.10 28.14 20.40 25.99
850 23.30 34.67 22.80 32.65 22.40 31.46 21.70 29.05
900 24.7 38.51 24.10 36.27 23.70 34.94 23.00 32.27
950 26.1 42.54 25.40 40.06 25.00 38.60 24.20 35.64
1000 27.4 46.76 26.80 44.03 26.40 42.42 25.50 39.17
1100 30.2 55.74 29.40 52.48 29.00 50.56 28.10 46.69
1200 32.9 65.45 32.10 61.62 31.60 59.37 30.60 54.82
1300 35.70 75.89 34.80 71.45 34.20 68.83 33.10 63.55
1400 38.40 87.05 37.40 81.95 36.90 78.95 35.70 72.89
1500 41.10 98.23 40.10 93.13 39.50 89.71 38.30 82.82
1600 43.90 111.50 42.80 105.00 42.10 101.10 40.80 93.34
1800 49.40 138.80 48.10 130.60 47.40 125.80 45.80 116.10
2000 54.90 168.90 53.50 158.90 52.70 153.10 51.00 141.30
2200 60.40 201.70 58.90 189.80 58.00 182.80 56.10 168.70
notes:
*s.p.s. copper and brass pipe.
No allowance has been made for age, dierence in diameter, or any abnormal condition of the interior surface. Any factor of safety must be estimated from the local
conditions and the requirements of each particular installation. It is recommended that for most commercial design purposes a safety factor of 15 to 20% he added to
the values in the tables.