Replacement Parts
Table Of Contents
- commercial & residential pumps
- Design Envelope Compass Circulators
- Astro 2 Circulators
- Astro 2 Hot Water Recirculation Systems
- Astro 2 24-hour timer
- Aquastat controls
- Astro Express 2 Hot Water Recirculation
- S&H 3-Piece Circulators
- 1050 & 1060 3-Piece Circulators
- E.2 Circulators
- E.2 Circulator Spool Pieces
- 4270 & 4270 Stock Motor Mounted Pumps
- 4360 Pump-in-a-Box
- 4380 Pump-in-a-Box
- Design Envelope 4300/4380 Pump-in-a-Box
- hydronic specialties
- circuit balancing valves (cbv)
- replacement parts
- parts look up
- competition circulator cross reference
- technical data
- Pump Formulas
- Pressures & Altitudes
- Freezing & Boiling Points
- Ethylene Glycol Properties
- Propylene Glycol Properties
- Water Properties
- Useful System Curve Formulas
- Pipe Maximum Pressures
- Hydraulic Resistance
- Pipe Information
- Pipe Fittings & Valves Friction Loss
- Water Flow Calculator
- Unit Conversions
- Typical Symbols
- Product Solution Outlines/Brochures
TECHNICAL DATA
199
|
HYDRONIC SOLUTIONS CATALOG
2 inch
type k tubing type l tubing type m tubing pipe *
1.959" inside diameter
.083" wall thickness
1.985" inside diameter
.070" wall thickness
2.009" inside diameter
.058" wall thickness
2.062" inside diameter
.1565" wall thickness
flow
(usgpm)
velocity
(ft./sec.)
head loss
(ft./100ft.)
velocity
(ft./sec.)
head loss
(ft./100ft.)
velocity
(ft./sec.)
head loss
(ft./100ft.)
velocity
(ft./sec.)
head loss
(ft./100ft.)
10 1.07 0.31 1.04 0.29 1.01 0.27 0.96 0.24
12 1.28 0.43 1.24 0.4 1.21 0.38 1.15 0.33
14 1.49 0.56 1.45 0.52 1.42 0.5 1.34 0.44
16 1.7 0.71 1.66 0.66 1.62 0.63 1.53 0.55
18 1.92 0.87 1.87 0.82 1.82 0.77 1.72 0.68
20 2.13 1.05 2.07 0.98 2.02 0.93 1.92 0.82
25 2.66 1.55 2.59 1.46 2.53 1.38 2.39 1.22
30 3.19 2.15 3.11 2.01 3.03 1.9 2.87 1.68
35 3.73 2.82 3.62 2.65 3.54 2.5 3.35 2.21
40 4.26 3.58 4.14 3.36 4.05 3.17 3.83 2.8
45 4.79 4.42 4.66 4.15 4.55 3.92 4.3 3.46
50 5.32 5.43 5.17 5.01 5.05 4.73 4.8 4.17
60 6.39 7.4 6.21 6.95 6.06 6.56 5.75 5.79
70 7.45 9.76 7.25 9.16 7.07 8.65 6.7 7.63
80 8.52 12.42 8.28 11.65 8.09 11 7.65 9.7
90 9.58 15.36 9.31 14.41 9.1 13.6 8.61 12
100 10.65 18.58 10.4 17.43 10.1 16.45 9.57 14.51
110 11.71 22.07 11.4 20.71 11.1 19.55 10.5 17.24
120 12.78 25.84 12.4 24.25 12.1 22.88 11.5 20.18
130 13.85 29.88 13.4 28.04 13.1 26.45 12.5 23.33
140 14.9 34.18 14.5 32.07 14.2 30.26 13.4 26.69
150 16 38.75 15.5 36.36 15.2 34.3 14.4 30.25
160 17 43.58 16.5 40.89 16.2 38.58 15.3 34.01
170 18.1 48.67 17.6 45.66 17.2 43.08 16.3 37.98
180 19.2 54.01 18.6 50.67 18.2 47.81 17.2 42.15
190 20.2 59.61 19.6 55.92 19.2 52.76 18.2 46.51
200 21.3 65.46 20.7 61.41 20.2 57.94 19.2 51.07
210 22.4 71.57 21.7 67.14 21.2 63.34 20.1 55.83
220 23.4 77.93 22.8 73.1 22.2 68.96 21 60.78
230 24.5 84.53 23.8 79.29 23.2 74.8 22 65.93
240 25.6 91.38 24.8 85.72 24.3 80.86 23 71.26
250 26.6 98.43 25.9 92.37 25.3 87.14 23.9 76.79
260 27.7 105.8 26.9 99.26 26.3 93.63 24.9 82.51
270 28.8 113.4 27.9 106.4 27.3 100.3 25.8 88.42
280 29.8 121.3 29 113.7 28.3 107.3 26.8 94.52
290 30.9 129.3 30 121.3 29.4 114.3 27.8 100.8
300 32 137.6 31.1 129.1 30.4 121.8 28.7 107.3
notes:
*s.p.s. copper and brass pipe.
No allowance has been made for age, dierence in diameter, or any abnormal condition of the interior surface. Any factor of safety must be estimated from the local
conditions and the requirements of each particular installation. It is recommended that for most commercial design purposes a safety factor of 15 to 20% he added to
the values in the tables.