Instructions / Assembly
2. DESIGN AND INSTALLATION CONSIDERATIONS 
    2.1 Directionality 
   AcoustAffix
™
 panels have three different installation methods. For all installation methods, please note the following in regard to 
directionality. Panels are designed to be installed in single panel width rows. All panels can be butted edge-to-edge within each 
row in the case of all installation methods. Rows can have panels join short edge-to-short edge (23-3/4", nominal 2' wide) or 
long edge-to-long edge (47-3/4" nominal 4' wide). Due to the directional finish of the product, Armstrong Ceilings does not 
recommend butting short edges to long edges.
    2.2 Edges 
 Field paint-able panels (item 2012) have square edges on all sides.
     Factory painted panels (items 2012WH/BL) have square edges on 
the 4' sides but have back-cut edges along the 2' sides.
     Because of this back-cut, butting the 2' sides of factory painted 
panels edge to edge will result in the visual of a notch that is 
0.385" x 0.90" (illus. 2.2).
    2.3 Exterior Installations 
 AcoustAffix panels are not intended for exterior use.
    2.4 Direct Attachment to Deck, Structure or Wall 
   These panels can be installed on ceilings of any slope or on walls when following the suspension and fastening instructions in 
this document.
    2.5 Plenum 
   Design limitations require relatively clear deck areas and are not suitable for plenum spaces with services or obstructions that 
interupt the attachment surface.
 2.6 Fire and Sprinklers 
     AcoustAffix panels, as with other architectural features located at the ceiling, may obstruct or skew the planned fire sprinkler 
water distribution pattern, or possibly delay or accelerate the activation of the sprinkler or fire detection systems by channeling 
heat from a fire either toward or away from the device. Please consult a fire protection engineer, NFPA 13, and the local codes for 
guidance where automatic fire detection and suppression systems are present.
 2.7 Attachment Strength Requirements 
    Overall system weight will combine the panels and the suspension system.
    • Panels weigh 1lb/SF
    • HD8906 Drywall Grid weighs 0.3lbs/LF
    • Metal or wood furring (refer to manufacturer)
     Fastener connections of the suspension system to building structure are specified by the contractor and must follow the 
manufacturer’s instructions and reference code.
    2.8 Product Durability 
     AcoustAffix are soft mineral fiber panels and are not recommended for installations below 6' above the finished floor, or in 
high-impact locations such as gymnasiums.