Specifications
T e s t & I n s p e c t i o n
64
© 2006, AFL Telecommunications, all rights reserved. SLP4-07-2000 Revision 1A, 5.05.06
Specifications are subject to change without notice.
SLP4-7 Triple Wave Test Kit with Wave ID and Set Reference
OPM 4-4D specifications
OPTICAL OPM 4-4D
Calibrated wavelengths 850, 980, 1310, 1490, 1550, 1625 nm
Detector type Filtered InGaAs
Measurement range +26 to -50 dBm
Tone detect range +6 to -30 dBm
+6 to -25 dBm for 850 nm
Wavelength ID range +6 to -30 dBm
+6 to -25 dBm for 850nm
Accuracy*
± 0.25 dB
Resolution 0.01 dB
Measurement units dB, dBm, µW
GENERAL
Power 2 x AA batteries, optional NiMH
Battery life (2 x AA) 300 hours with backlight [Off]
20 hours with backlight [On]
Operating temperature -10 to 50°C, 90% RH (non-condensing)
Storage temperature -30 to 60°C, 90% RH (non-condensing)
Size (H x W x D) 5.5 x 3.2 x 1.5 in (14.0 x 8.1 x 3.8 cm)
Weight 0.58 lb (0.26 kg)
* Accuracy measured at 25ºC and -10 dBm per N.I.S.T. standards.
All specifications at 25°C
OLS7 Specifications
OPTICAL MODEL OLS7 - FTTH MODEL OLS7
Wavelength (±20 nm) 1310 nm 1490 nm 1550 nm 1310 nm 1550 nm 1625 nm
Spectral width 5 nm 3 nm 5 nm 5 nm 5 nm 2 nm
Output power -5 dBm (typical) into 9/125 fiber
Emitter type Laser, Class I (FDA 21 CFR 1040.10 and 1040.11)
Output stability ± 0.05 dB over 1 hr. (after 15 min warm-up, after 30 sec typical)
± 0.1 dB over 8 hrs (after 15 min warm-up, after 30 sec typical)
Connectors UCI based adapters: SC standard, FC & ST available, LC optional
Tone output 270 Hz, 330 Hz, 1 kHz, 2 kHz
GENERAL MODELS OLS7 - FTTH & OLS7
Power 2 AA alkalines. Optional: NiMH rechargeables or external AC adapter
Battery life Minimum 85 hours (with one laser active)
Operating temp. -10° to 50°C, 90% RH (non-condensing)
Storage temp. -30° to 60°C, 90% RH (non-condensing)
Size (H x W x D) 5.5 x 3.2 x 1.5 in (14.0 x 8.1 x 3.8 cm)
Weight 0.66 lb (0.3 kg)
All specifications at 25°C
P A S S I V E I N F R A S T R U C T U R E