Specifications

46
© 2002, AFL Telecommunications, all rights reserved. Revision 1, 6.14.06
Specifications are subject to change without notice.
Non-Armored Loose Tube Cable –
Single Jacket
Temperature Range
Operating . . . . . . . . . . . . .-40ºC to +70ºC
Storage . . . . . . . . . . . . . . .-40ºC to +75ºC
Installation . . . . . . . . . . . . .-30ºC to +70ºC
Acting as the backbone for most of today’s fiber based systems, stranded fiber optic cables
play a critical role in the high speed network. AFLs Non-Armored Loose Tube fiber optic cables
are designed to provide high fiber counts with the flexibility and versatility required for today’s
most demanding installations. Our cables feature fiber counts up to 576, compliance with EIA/
TIA and REA/RUS PE-90, and are S-Z stranded for easy mid-span access. Industry standard
designs combined with innovative technologies, such as a dry core product, yield a world class
cable that will support today’s and tomorrow’s technological needs.
Product Applications
Long Haul Networking
Building Interconnections (Campus LAN)
Trunking Lines Direct to
Telecommunications Closet
Local Loop
Distance Learning
Distribution
Intrabuilding Backbones
Cable Components
Typical Lengths
MAXIMUM LENGTHS*
FIBER
COUNT
SINGLE-MODE MULTIMODE
FEET METERS FEET METERS
6 - 60 28,500 8,700 26,200 8,000
72 - 96 32,800 10,000 26,200 8,000
108 -120 31,100 9,500 26,200 8,000
132 - 144 22,900 7,000 23,000 7,000
146 - 216 22,900 7,000 20,000 7,000
218 - 288 16,400 5,000 16,400 5,000
290 - 432 14,100 4300 14,000 4,300
434 - 576 10,800 3300 11,000 3,300
* Longer lengths may be available upon request.
Optical Information
FIBER TYPE
MAXIMUM ATTENUATION
(dB/km)
OVERFILL LAUNCH MIN.
BANDWIDTH (MHz•km)
GIGABIT ETHERNET MIN.
LINK DISTANCE (METERS)
850nm 1300nm 1310nm 1550nm 850nm 1300nm 850nm 1300nm
(6) 62.5/125 GIGA-Link™ 300 3.5 1.2 N/A N/A 200 600 300 550
(8) 62.5/125 GIGA-Link™ 1000 3.5 1.2 N/A N/A 350 600 500 1000
(5) 50/125 GIGA-Link™ 600 3.5 1.2 N/A N/A 500 500 600 600
(7) 50/125 GIGA-Link™ 2000 3.5 1.2 N/A N/A 500 800 750 2000
3.5
1.2
N/A
N/A
1500
500
900
550
(9) Single-mode N/A 0.4 0.4 0.3 N/A N/A N/A N/A
(K) SM Futureguide SR-15e Bend Insensitive N/A 0.5 0.5 N/A N/A N/A N/A 5000
Gigabit Ethernet Minimum Link Distances are based on “bandwidth”/modal dispersion constraints.
Actual link distances may be constrained by attenuation, depending on specific loss budget.
P A S S I V E I N F R A S T R U C T U R E