Technical data

25
3.2 CONTROLS AND INDICATORS
CAUTION:
DO NOT force the equipment controls past their stopping points.
3.2.1 COMINI CONTROLS AND INDICATORS
TheCO-MINIcontrolsareshowninFigure3-14.
The CO-MINI controls and indicators are dened in Table 3-1. The ITEM NO. column indicates the num-
berusedtoidentifyitemsinFigure3-14.
TABLE 31. COMINI CONTROLS AND INDICATORS
ITEM NO. CONTROL/INDICATOR FUNCTION
1 Turn-push Switch Activates the CO-MINI when turned CW from OFF to ON. The
switch must be pushed to turn the device on.
Activates the standby mode when turned CCW from OFF to STB.
The switch must be pushed to switch to STB.
Deactivates the CO-MINI when turned from ON/ STB to OFF.
2 GainControlKnob* Adjusts the brightness of the image.
Remote Control Button Activates/deactivates the CO-MINI in standby when pressed/
released.
3 Pivoted Shutter Closes/opens the photoreceiver when placed in the highest/low-
est position.
Built-in Bi-color LED
Indicator
PERMANENT YELLOW GLOW in the viewing area indicates exces-
sive light conditions. After 10 seconds of exposure to excess light,
theimageintensiertubewillbecuto.TheCO-MINIwillturn
back on when moved away from the excessive light.
A FLASHING RED LIGHT in the viewing area indicates a low bat-
tery. The LED will ash three times every 3 minutes.
* For CO-Mini MG version only.
FIGURE 314. COMINI CONTROLS
3
1
2