Technical data
21
3.1.4 CLAMPING DEVICE ADJUSTMENT
Adjust the mount clamping device as follows (refer to Figure 3-6):
1. Unlock the clamping device and remove the CO-MINI from the weapon.
2. To tighten or loosen the clamping device, push the cam (C) towards the arrow. This will cause the nut
(A) to slide out of the hollow. Turn the nut (A) CW/CCW respectively, in one-two increments (see note
below). Much like when the cam (C) is released, the backward-moving springs in this mechanism will
cause the nut (A) to slide back into the hollow.
NOTE:
The eight-sided nut of the clamping device will only t into the hollow if turned in one of the
discretepositionsusingincrementsequalto360°/8.
3. Verify that the adjusted clamping device rmly holds the CO-MINI.
3.1.5 MOUNTING THE COMINI IN FRONT OF AN ACOG 4×32 SCOPE
WhenmountingtheCO-MINIinfrontofanACOG4×32scope,usetheoptionalraiserandlightsup-
pressor ACOG.
TomounttheCO-MINItoaPicatinny/WeaverrailinfrontofanACOG4×32,dothefollowing(referto
Figure 3-7):
1. Usinga2.5mmAllenkey,unscrewbothoftheМ4×8xingscrewsoftheCO-MINImount.Removethe
device from the seating rail.
2. Apply a small amount of thread lock to the threads. Secure the raiser (A), together with the mount (B),
totheseatingrail(D)withtwofurnishedМ4×18screws(C).Usea2mmAllenkey.
A
B
C
D
FIGURE 37. INSTALLING THE MOUNT WITH THE RAISER
FIGURE 36. MOUNT. UNDERSIDE VIEW
A B
C
UNLOCK
POSITION
LOCKED
POSITION