Technical data

17
2.3.3. ELECTRONIC CIRCUIT FUNCTION
The electronic circuit regulates the direct current voltage from the battery to the image intensier and
IR source as required. It also monitors the output voltage of the battery and turns on a low-battery
indicator when the available battery voltage is 1.9 – 2.1 Vdc.
a. Power Source
The electronic circuit is powered by one battery.
b. High Light Cut-O
The monocular will automatically turn o after 70 ±30 seconds of operation in daylight or other bright-
ly lit environments. Individual bright lights (headlights, ashlights, or other concentrated light sources)
will not actuate the high light detector located on the front of the monocular. To turn the monocular
back ON, turn the power switch to RESET/ OFF, and then to ON again.
PHOTOCATHODE
MICROCHANNEL
PLATE
FIBER-OPTIC
INVERTER
OBJECTIVE
LENS
PHOSPHOR
SCREEN
IMAGE
INTENSIFIER
POWER
SUPPLY
EYEPIECE
LENS
EYE
Figure 2-6. Optical Function Diagram