4.2 OPERATOR TROUBLESHOOTING
The purpose of troubleshooting is to identify the most commonly occurring equipment malfunctions,
their probable causes, and the corrective actions required to x them.
Table4-2liststhecommonmalfunctionsthatmayoccurduringtheoperationormaintenanceofthe
CO-MR. Perform the tests, inspections, and corrective actions in the order listed in the table.
This table cannot list all of the malfunctions that may occur with your CO-MR, or all of the tests
and corrective actions that may be necessary. If you experience an equipment malfunction that is
not listed, or is not xed by the corrective actions listed in the table, please contact Armasight’s Cus-
tomer Service center.
TABLE 42. OPERATOR TROUBLESHOOTING
MALFUNCTION PROBABLE CAUSE/ TEST/INSPECTION CORRECTIVE ACTION
CO-MR fails to activate. Battery is missing or improperly installed. Insert battery or install correctly.
Battery is dead. Replace the battery.
Battery surfaces or contacts are dirty or
corroded.
Clean the contact surfaces with a pencil eraser
and/or alcohol and cotton swabs.
Remote control unit is damaged. Please contact Customer Support.
Remote control batteries are dead. ReplacethebatteriesasperPart4.4.3.
Defective image intensier tube. Please contact Customer Support.
Poor image quality. Check focus. Refocus.
Objective and output lenses are dirty. Thoroughly clean the surfaces of each lens.
Damaged optical components. Please contact Customer Support.
LED indicator fails to activate. Visual inspection. Please contact Customer Support.
CO-MRaectsboresightafter
installation or during the ring.
Factory alignment is broken. Please contact Customer Support.
Hinderedrotationofthebat-
tery cap.
Dirty cap thread. Clean the thread.
Damaged cap thread. Please contact Customer Support.
Battery adapter dicult to re-
move.
Check for damaged battery adapter and
battery cap.
If damaged please contact Customer Support.
Light visible around light sup-
pressor.
Incorrect position of the CO-MR in relation
to the day scope.
Reposition the CO-MR on the Picatinny/ Weaver
rail.
Check the light suppressor resilience. If light suppressor is defective please contact Cus-
tomer Support.
IR850 fails to activate. Battery is missing or improperly installed. Insert battery or install it correctly.
Battery is dead. Replace the battery.
IR850 damaged. Please contact Customer Support.
4.3 IDENTIFICATION OF OPERATIONAL DEFECTS
4.3.1 OPERATIONAL DEFECTS
Operational defects relate to the reliability of the intensier, and are an indication of instability. If iden-
tied, the user will need to return the CO-MR immediately. Operational defects include shading, edge
glow, ashing, ickering, and intermittent operation.
A. Shading
Ifshadingispersistent,youwillnotbeabletoseeafullycircularimage(Figure4-1).Shadingisavery
dark, high-contrast area with a distinct line of demarcation present, and you cannot see an image
through it. Shading always begins on the edge, and will eventually migrate inward until it spans across
the entire image area. If you notice shading with your device, please contact Customer Support.