NOTE:
Automatic interrupting time is 60 minutes. To resume operation, you will need to restart the
CO-MR..
3.3.2 OPERATING THE IR850
Use the IR850 in poor light conditions or complete darkness.
CAUTION:
ThelightfromtheIRilluminatorwillbeinvisibletothenakedeye.However,thelightcanbe
detected by other NVDs.
CAUTION:
DO NOT leave the IR850 activated when the device is not in use.
1. After examining a scene with the CO-MR, turn the IR850 on.
2. To change the radiated power level, turn the power switch to one of the spots between the two OFF
positions.
3. To adjust IR beam divergence, turn the lens.
4. ToadjusttheIRspotpositionintheeldofview,loosentheclampscrewandtilttheIR850asre-
quired in the spherical clamp hinge. Tighten the screw using a 2.5 mm hex key.
3.3.3 OPERATING IN CHANGING LIGHT CONDITIONS
If a mission must be carried out in changing light conditions, you can deactivate the bright light protec-
tion system of the CO-MR. To shut down the protection system, close the photoreceiver with the cap.
CAUTION:
After your mission is complete, open the photoreceiver by removing the cap.
3.3.4 SHUTDOWN
Shut-down the CO-MR as follows:
1. Turnothedevice.Thegreenglowwilldisappear.
2. Place the cap over the objective lens.
3. Place the cap over the LED indicator.
4. RemovetheCO-MRfromtheweapon/dayscopelens.
5. Remove the light suppressor from the output lens.
6. Screw the cap into the output lens thread.
7. Remove the IR850 from the CO-MR.
8. Remove the batteries.
CAUTION:
DO NOT store the equipment with the battery still in it.