Manual

24
3.3. OPERATING PROCEDURES
NOTE:
When operating the LAD’s IR channel(s), you must wear night vision
goggles.
CAUTION:
DO NOT force the equipment controls past their stopping points.
3.3.1 BORESIGHT ADJUSTMENT PROCEDURE
NOTE:
Before adjusting the LAD boresight for the rst time, re approximate-
ly 10 shots from the weapon with the device installed, in order to sta-
bilize the adjustment mechanisms under applied shocks.
NOTE:
When adjusting the equipment boresight, beware of reections from
optical surfaces.
To adjust the boresight:
1. Locate a target at the re adjustment range (100m).
2. Take aim at the center of the target using the weapon’s iron sight; secure
the weapon in the aiming rest.
3. Unscrew the caps from the adjustment screws.
4. Remove the cap from the output aperture of the aiming laser.
5. Turn the switch to the required position, and activate the LAD (push
ON).
6. Using a screwdriver
To shift the aiming dot to the right, turn the windage adjustment screw
CCW. To shift it to the left, turn the screw CW.
To shift the aiming dot down, turn the elevation adjustment screw
CCW. To shift it up, turn the screw CW.
7. Fire a series of shots.