3. The Receivers ID Code matching / Failsafe Protection
Press the SET button on the receiver for 10 seconds, then the receiver enters the ID code waiting status, LED
flickers fast (5 times per second). Now reopen the transmitter to match Code. If succeeded, the receiver will
automatically enter into the FHSS working condition.
Press the SET button of the receiver for 5 seconds, set the failsafe protection. (The LED will flicker slowly
for 3 times after the setting.)
If the receiver is receiving the signal, the status LED will flicker fast, otherwise flicker slowly (one second
one time).
4. Receiver Single-line PPM & RSSI Output
Make a short circuit between the Channel 8s signal to the 5V (in the middle row) using jumper cap. Then
channel 7 will output composite PPM signal. It can be connected to Arkbird OSD s AR port, and make single-wire
transfer of the 10 channels and RSSI value.
On the Arkbird OSD, the original 1-4 channel input ports which used to connect common receivers,
automatically become output ports which will output the controlling value of channel 7-10 of the remote control.