TABLE OF CONTENTS GENERAL INFORMATION General information..................................................................................... 2 Transport, storage and unpacking.............................................................. 2 Technical data............................................................................................... 3 Functional description.................................................................................. 4 Safety and alarms................................
TECHNICAL DATA ARITERM BIOMATIC+ • • • • • • • • • • • • Standard delivery Four-way mixing valve ESBE TM 20 Sweeping gear Dirt trap Brick support Flue duct joint Shunt motor ESBE ARA661 3-point SPDT 230Vac 6Nm 120s Outdoor temperature sensor Indoor temperature sensor Supply water temperature sensor Automatic convection cleaning system Flow switch Flue gas fan • • • • Accessory Combined flue duct Oxygen measurement (Z19014) Heating circuit 2 Unit for interior temperature (14101) TECHNICAL DATA P
FUNCTIONAL DESCRIPTION SAFETY AND ALARMS Heating with the Ariterm Biomatic+ pellet heating centre is similar to oil heating in many ways. The main difference is that heating with solid fuel produces a certain amount of ash, which must be removed at certain intervals. If the ash is not removed, combustion efficiency will decrease and the burner may malfunction. The BeQuem pellet burner is equipped with automatic ignition. However, it can also be ignited manually when necessary.
BURNER OPERATING PRINCIPLE CONTROL PANEL 2 3 4 1. 2. 3. 4. 5. 6. Temperature Boiler 80(80)°C Flue gas -40°C Burner off (on) Auger, external Manual operation off 7.
BOILER INSTALLATIONS BOILER INSTALLATIONS The boiler should be installed by a company with the proper professional qualifications. The installation must always be carried out in accordance with, at the time being, valid local standards and regulations. NOTE! All electrical connections must be carried out by a professionally-qualified electrician. Space requirement The boiler room must always meet, at the time being, valid local standards and regulations.
PIPE INSTALLATIONS VV VW KV CW TV DW ARITERM-VTT-S-07229-11.1 1. ARITERM BIOMATIC+ 2. 4-WAY VALVE, FLOOR HEATING (RADIATOR HEATING) 3. CONNECTION SET OF THE ADDITIONAL HEATING CIRCUIT (RADIATOR HEATING) 4. HEAT PIPE PUMP, FLOOR HEATING 5. HEAT PIPE PUMP, RADIATOR HEATING 6. FLOOR HEATING NETWORK MANIFOLDS 7. RADIATOR HEATING NETWORK 8. EXPANSION VESSEL 9. SERVICE SHUT-OFF VALVE 10. SAFETY VALVE 11. FILLING VALVE 12. FEED MIXING VALVE 13.
WIRING DIAGRAM ARITERM-VTT-S-07229-11.1 ARITERM SWEDEN AB • ARITERM OY • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.
START-UP AND STOP Burner start-up and stop Turn the burner and the internal pump on from the operating switch. If the flow switch that controls the internal pump is on, set the operating switch to Off mode. The main menu, which shows the temperatures of boiler water and flue gases, will appear on the display. The main menu also shows the Start-up/Stop setting and mode of the burner. If the buttons are not pressed for 10 seconds, a graphic showing temperature and burner data will appear on the display.
BURNER SETTINGS BURNER PARTS The settings for combustion and burner operation can be found in the Power menu. Combustion adjustment In most cases, the factory settings are sufficient for proper and efficient combustion. In addition, they can be applied when the underpressure in the combustion chamber is about 8-15 Pa and the pellets used have a diameter of 8 mm. In connection with commissioning, it is recommended that the values be adjusted by a skilled installer by means of a flue gas analyser.
MENU STRUCTURE Main menu Operating time Adjustment Test outputs Temperature • Boiler • Flue gas Total El step Auger external Max Start backup El Fan Residual oxygen Low Level monitor Auger burner Burner off (on) Min Optical monitor Ignition Fuel El 1 Test outputs El step Auger external • Manual El 2 English Load pump Default settings Conv.
MENU STRUCTURE The following tables give an overview of the messages that may appear on the display of the control unit. They also indicate which parameters the user is allowed to change freely and which parameters he/she is allowed to change only if instructed to do so by an authorised installer. NOTE! Part of the menu options are displayed only when they are active.
MENU STRUCTURE Pellet store menu pellet store and consumption monitoring Text on the display Setting Power settings menu Displays the amount of pellet fuel remaining in the store. A new value can be set in connection with a change in the pellet store. Displays how many days the pellets in the store will last at the average consumption level in question. Pellet store x.x t 0.0-25.0 t Displays the amount of pellet fuel remaining in the store. A new value can be set when reloading the pellet store.
MENU STRUCTURE Accessories menu Menu Setting Description Residual oxygen On/Off Fan power adjustment according to residual oxygen. The oxygen value can be seen in the main menu and in the graphic. Heating circuit On/Off Heat regulation of two heating circuits possible. Menu Shunt control 2 is visible, when the sensor is connected.
HEATING CIRCUIT SETTINGS HEATING CIRCUIT SETTINGS Menu Setting Description HeatingCurve 22-56 °C Temperature graph determination (outdoor temperature 0 ºC) See the curve! Flow water min 0-30 °C Supply water minimum temperature Flow water max 30-85 °C Supply water maximum temperature Curve comp. +5 °C 0-5 °C Heating circuit graph compensation with an outdoor temperature of +5 °C Curve comp. 0°C 0-5 °C Heating circuit graph compensation with an outdoor temperature of 0 °C Curve comp.
HEAT REGULATION EXAMPLES HEAT REGULATION MENU STRUCTURE The following section contains examples of the different heating systems and their settings. The settings are indicative and fine adjustment might be required. Drop menu Menu Setting Description Drop Off, 1-5, 1-7, 6-7 Days when drops are to be carried out. 1-5 = Mon-Fri, 1-7 = Mon-Sun and 6-7 = Sat-Sun Start 00.00 - 24.00 Time at which the drop starts Stop 00.00 - 24.
ROOM TEMPERATURE UNIT, INSTALLATION AND USE - accessories LAMBDASOND metering residual oxygen - accessory Room temperature, set value Room temperature Open the hatch Outdoor temperature Electrical resistor symbol Control buttons Boiler water temperature The Pellet boiler Ariterm Biomatic+ can be equipped with a heated oxygen sensor that facilitates control of the burner and which if necessary can regulate the combustion air fan output if the combustion is poor.
ALARMS AND TROUBLESHOOTING In case an alarm becomes active, this is indicated by the burner on the display of the control panel with a red light and a text message. This facilitates troubleshooting, because the user can see the cause of the problem. The burner stops in connection with an alarm. The cause of the fault must be determined before switching the device on again. If an alarm is given often, this may be due to incorrect adjustments/settings.
ALARMS AND TROUBLESHOOTING Alarm message / Cause Check that Procedure Alarm message / Cause Check that Procedure the boiler sensor is in place and the wires are intact. If the boiler sensor wire is not connected or is broken, the sensor shows the reading 0°C and the alarm is activated. 1. the bypass damper of the boiler is in place. 2. the flue gas sensor is in the flue gas channel. 1. Put the bypass damper in place 2. Place the flue gas sensor in the flue gas channel. Alarm boilersensor 1.
GUARANTEE AND DECOMMISSIONING Guarantee For Warranty Issues Ariterm Sweden AB refers to our local Distributor. Decommissioning An end-of-life boiler is suitable for scrapping. Its plastic parts are landfill waste. MOST COMMON SPARE PARTS Product no. 5936 Overheat protection EGO 55.33412.
SERVICE AND MAINTENANCE The boiler and burner will function without problems for a long time if the following instructions are observed: • The boiler must be kept in a dry environment • The boiler and burner operate all the time within the defined adjustment values. • Clean the boiler when the temperature of flue gases has increased by 20-30°C with respect to the temperature they have with a clean boiler. • Check the burner head and clean it as needed.
BOILER CLEANING Automatic convection cleaning system The boiler is equipped with automatic convection cleaning system that automatically carries out the sweeping at certain intervals. In any case, the convection channels must be cleaned (swept) two times a year. The cleaning is done through the cleanout hatch on the top of the boiler. The automatic sweeping system must be removed before sweeping. Disconnect the main power before maintenance work.
DISASSEMBLY OF THE AUTOMATIC CLEANING / CLEANING SOOT FROM THE CONVECTION UNIT 1. Open the outer and intermediate star knobs and lift off the soot hatch. 2. Lift the lift lever up. 3. Lift the rocker switch to the side. 4. Lift the lift lever up, remove the hatch for the convection channel. 5. Lift off the second hatch of the convection channel. 6. Lift off the holder and the springs from the convection. 7. Sweep the convection pipe surface with a brush, remove any ash.
WOOD PELLETS AS FUEL Wood pellets are renewable bioenergy and provide fuel in a compact and uniform form, which is easy to handle. The moisture content is less than 10%, which means that the pellets do not freeze or become mouldy. No chemical substances are used in the manufacturing process. Instead, the binding agent is the tree’s own lignin.
FEEDING SYSTEM Weekly silo PF300 The lightweight silo is an alternative to the self-built silo. The practical PF300 may also be used as intermediate store for pellets. The capacity of the pellet silo is 300 litres and its filling is facilitated by the intermediate grid in the silo. Contrary to the figure, the silo is delivered with a lid. NOTE! More information on the installation of PS300/Feedo can be found in separate manuals. ARITERM-VTT-S-07229-11.
DECLARATION OF CONFORMITY The Clean Air Act 1993 and Smoke Control Areas Under the Clean Air Act local authorities may declare the whole or part of the district of the authority to be a smoke control area. It is an offence to emit smoke from a chimney of a building, from a furnace or from any fixed boiler if located in a designated smoke control area.
INSTALLATION REPORT After installation, the burner must be adjusted using a flue gas analyser. Flue gas temperature - Max CO O2 CO2 Combustion efficiency Draught mm Blower % Auger % Flue gas temperature - Mean CO O2 CO2 Combustion efficiency Draught mm Blower % Auger % Flue gas temperature - Min CO O2 CO2 Combustion efficiency Draught mm Blower % Auger % Dealer / Installer Installer Date ARITERM-VTT-S-07229-11.
NOTES ARITERM-VTT-S-07229-11.1 ARITERM SWEDEN AB • ARITERM OY • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.
NOTES
NOTES ARITERM-VTT-S-07229-11.1 ARITERM SWEDEN AB • ARITERM OY • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.
NOTES ARITERM-VTT-S-07229-11.1 ARITERM SWEDEN AB • ARITERM OY • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.
ARITERM-VTT-S-07229-11.1 ORGANISATION CERTIFIED BY ARITERM SWEDEN AB | Flottiljvägen 15 39241 Kalmar | www.ariterm.