Operation Manual

- 18 -
Figure 3
Examples of messages:
message 1: “Burglar alarm”
message 2: “Fire alarm”
message 3: “Medical assistance requested”
message 4: “Panic alarm”
message 5: “Care of Jones, 5 The High Street in Wolverhampton”
Start playback
All recorded messages can be played back through the connected telephone device.
For the user.
After receiving an alarm call via the voice module, the dialler will generate a beep tone.
The user can then do the following:
1. Enter the
00
00
0 button on his telephone keypad. The connection is cut off.
2. Entering the
11
11
1 button to start a 45 sec Audio-listen-in period
3.6 Test call
The dialler is equiped with test call functions which can be activated automatically or manually.
3.6.1 Test delay hh
Set a “delay” time before the first automatic test call is sent to the central station. In this way the test calls
can be programmed a few days in advance (max.24 hours) to occur at a particular time in the week.
Example: You program the automatic test call for every 24 hours and you want the test call to be re-
ceived at the central station at 03:00 hrs. If you exit the installation at 17:00 hrs, you must therefore set
the DELAY to 10 hours. The first test is then sent at 03:00 hrs, and the subsequent tests are continued at
24-hour intervals (i.e. always at 03:00 hrs)
The time starts as soon as the new parameters are accepted.
3.6.2 Test call time hhh
Program the length of time between two test calls in hours (from 0 to 254 hours).
3.6.3 Always Test
If this option is set to [NO], the dialler will only send a test call if no other messages have been sent
within the test call interval.