Installation manual
Installation manual for the CD3403 Page 7
4.
Supply only mains power to the control panel. The system will power up in the ARMED state. Any
zones that may be open will initiate a full alarm condition and the sounders will activate.
Do not use a battery to power the system when installing or changing the installation. If there is a
short circuit in the 12 volt power supply, the voltage regulators in the supply (together with the fuses)
will prevent serious damage to the system The 12 volt power supply will decrease sharply in the
event of a short circuit.
If a short circuit should occur, remove the 12 volt connections one by one. When the connection with
the short circuit is removed the power supply will return to 12 volts.
NOTE: ONLY KEYPAD ONE IS OPERATIONAL.
Every time power is removed from the system the control panel memorises its status. If power is
restored to the panel, the system starts up again in this status (except if JP1 has been removed).
5.
Enter
‘0’
followed by the default user code
‘1122’
at keypad 1.
'Disarm?’
is shown on the display.
System then disarms after pressing the ‘
!
!!
!
‘ button.
If the sirens have been activated, these will now stop. The status of the system or the time and date
will now appear in the display.
6.
Enter
‘0’
followed by the default engineer’s code
‘1278’
at keypad 1 and press
‘
"
""
"
’
to return to
programming mode.
N.B.
Do not forget to initialise additional keypads and expanders with the menu 5.2, ‘INSTALL REMOTE’
Replace JP1.
P
ROGRAMMING GUIDE
Always enter a ‘0’ before entering an engineer/user code to prevent errors !
Under keys 1 to 9 there are 3 letters of the alphabet:
press the keys repeatedly to enter first the number,
then the lower case letters and then the upper case
letters. Keys 9 and 0 have special symbols such as
the comma and space.
The arrows move the cursor during entry.
Press
‘
!
!!
!
’
to accept an entry.
Cancel an entry by pressing
‘X’
.
To delete a character, overwrite with another
character or a space.
Note: CD30xx stands for the keypads:
CD3008, CD3048, CD3009 and CD3049
R
ETURNING TO DEFAULT SETTINGS
There are two methods of returning the system (not the dialler) to default settings, these are:
DISPLAY
ABC
1
DEF
2
GHI
3
JKL
4
MNO
5
PQR
6
STU
7
VWX
8
YZ
9
Cursor left
#
0
Cursor right
"
down up
End
Accept
X
!
Figure 3.
Keys on a CD30xx