Installation manual

Page 18 Installation manual for the CD3403
Z
ONES
Zone Types Zone Options
No. Standard Standard
1
Exit/Entry 1 InCh
2 to 10
Alarm In
Table 4.
Input default settings
Zones 7 to 10 are only available when the panel is expanded using the plug-in CD3004 expander or the
CD3048/3049 keypads.
O
UTPUT
The outputs can be represented as switches that connect the output to ‘Negative.’
If you program an output for activation as ‘-’, the switch is closed on activation and the output is
negative. If it programmed as ‘+’, on activation the switch is open and the output is +12 Vdc via the
4k7 resistor.
Alternations to output programming only takes effect after leaving programming mode.
Outputs 1 to 4 can provide
100mA
, the outputs of the internal siren (5) and external siren (6) can switch
1A.
ATTENTION:
Outputs are switched to negative. Connect
devices
between +12V and the output.
Figure 16.
LED or relay connection to outputs
(dotted box shows the principle of an output)
Output
No. Standard
1
PA +
2
Fire +
3
Alarm +
4
Disarm/Arm -
5
Internal siren -
6
External siren
Table 5.
Default output settings
Keypad buzzers are preprogrammed
and cannot be accessed. Keypad output
OB on CD3048/3049 keypads cannot be
used.