5
Model number
Burner Variants
Wok
burner
Semi-rapid
burner
Total
Dimensions
TH 721 D22 B/NG
2
0
9kW
(760 X 450)mm
TH 731 D2/A B/NG
2
1
10.7kW
(760 X 450)mm
TH 931 D2/A B/NG
2
1
10.7kW
(860 X 500)mm
TH 721 D22 E/NG
2
0
9kW
(760 X 450)mm
TH 731 D2/A E/NG
2
1
10.7kW
(760 X 450)mm
TH 931 D2/A E/NG
2
1
10.7kW
(860 X 500)mm
Note:
Wok burner = Rated at 4.5kW
Auxiliary burner = Rated at 1.7kW
Burner
Injector
size(mm)
Injector
marking
Full rate
kW
For LPG
Wok
Inner ring
0.4
40
4.5
Outer ring
0.95
95
Auxiliary
0.65
65
2
For TG(G110)
Wok
Inner ring
1.3
130
4.5
Outer ring
2.9 290
Auxiliary
2.2
220
2.3
For NG
Wok
Inner ring
0.6
60
4.5
Outer ring
1.4
140
Auxiliary
0.95
95
1.7