Technical data

7
3. TECHNICAL DATA
Operating pressure and
temperature must be within
the limits depicted by the
hatched area
Operating temperatures above
100°C as depicted by the
shaded area must be avoided
for continuous operation
FIG. 3.1A TEMPERATURE PRESSURE DIAGRAM
3.1 TEMPERATURE / PRESSURE
PUMP MODULE
Pipe connection 22mm
Reducers supplied 15mm
Pump type 15/40
Maximum operating pressure 0.6MPa
Electrical Cable 1.0mm² 3 core heat resistant flex 3093Y to 85°C
Cover Moulded polystyrene
AIR SEPARATOR MODULE
Pipe connection 22mm
Reducers supplied 15mm
Maximum operating pressure 0.6MPa
Cover Moulded polystyrene
EXPANSION VESSEL
2 & 3 collector systems 25l
Optional size (code 12002737) 35l
Maximum pressure 10 bar
Pre-charge pressure 2.5 bar
PRESSURE RELIEF VALVE
Setting 6 bar
Discharge ½” BSP - Ø15 pipe
HEAT TRANSFER FLUID
Type Tyfocor LS
Use undiluted 100%
Weight 1.04kg/l
Frost protection to -28°C