Technical information

Ø 80 mm
In addition, it is also possible to use a split (twin pipe)
system b
y fitting a special adaptor to the flue connector
and using the aperture for the air vent intake located on
the top par
t of the combustion chamber.
To utilise the air intake it is necessary to:
1. Remove the bottom of the air intake by cutting it with a
suitable knife (see FIG. 2.7);
2.
Insert the elbow into the air intake until it reaches the
lo
wer end. (There is no need to use gaskets or sealing
compounds).
11
IMPORTANT!
For all flue systems, a restrictor
must always be inserted into the
boiler’s flue connector; the
restrictor must be Ø 46 or Ø 41 in
diameter depending on the length
of piping indicated in T
ABLE 2.1.
FIG 2.9 and FIG 2.10 illustr
ate some
of the various designs for coaxial or
twin pipe flue systems.
F
or further information on
discharge/ventilation accessories,
see the
FLUE PIPE ACCESSORIES
MANUAL.