Technical information

27
installation
Electrical diagram
For increased safety, ask a qualied technician to perform a thorough check of the electrical system.
The manufacturer is not responsible for any damage caused by the lack of a suitable earthing system or by the
malfunctioning of the electricity mains supply.
CN14
DISPLAY
CN25
CN17
CN19
CN26
FAST FUSE 2A
1
CN05
FLAME
CN04
EARTH
1234
CN22
N L
CN20
FILLING EXT. P.
1 2 3 4
CN12
FAN PUMP
PUMP
SPEED
1 2 3 4 5 6
CN10
DIV. VALVE
CN08
8 7 6 5 4 3 2 1
CN11
1213 11 10 9 8 7 6 5 4 3 2 1
CN12
11 10 9 8 7 6 5 4 3 2 1
CN24
CN21
5 4 3 2 1
2
1
CN16
230 V - 2A
Fusible de protection
230 V - 2A
Electrode
ionisation
5
1
Achage
Sonde
extérieure
Allumeur
Vanne Gaz
Circulateur
Vanne
distributrice
Electrovanne
remplissage
Thermostat
plancher
chauant
Thermostat
d’ambiance
Débistat
sanitaire
Sonde sanitaire
Sonde pression
circuit primaire
Ventilateur
Thermofusible
échangeur
Sonde retour
circuit primaire
Sonde départ
circuit primaire
1213 11 10 9 8 7 6 5 4 3 2 1
CN24
B- Platine autres options
Sonde solaire
P
11 10 9 8 7 6 5 4 3 2 1
2
1
CN16
CN12
B
Commande
à distance
N
M
B
N
B
M
B
M
N
N
G
G
M
M
N
N
Bl
R
B
N
M
B
M
N
G
R
R
V
V
N = Noir
B = Bleu
Bl = Blanc
R = Rouge
V = Vert
M = Marron
G = Gris
M
B
N
N
N
N
N
G
G
Ignitor
Detection
electrode
Gas
valve
Display
Circulation
pump
Diverter valve
C.H. ow
temp. probe
thermal fuse
modulating fan
C.H. return
temp. probe
D.H.W ow
switch
Low water pressure
switch
Fuse
T/A room
thermostat
Blaxk
Blue
White
Red
Green
Brown
Grey
Optional board plate