Technical information

40
It is recommended that the following inspections be carried out
on the boiler at least once a year:
1 - Check the seals for the water connections; replace any faulty
seals;
2 - Check the gas seals; replace any faulty gas seals;
3 - Visual check of the entire unit;
4 - Visual check of the combustion process or analysis of
combustion by-products (see
SE
CTION
3.4) and cleaning of the
burner if needed;
5 - If necessary, dismantling and cleaning of the combustion
chamber;
6 - If necessary, dismantling and cleaning of the burner jets;
7 - Visual check of the primary heat exchanger:
- check for overheating in the blade assembly;
- clean the exhaust fan if needed;
8 - Adjustment of the gas pressure, gas rate and soft-light, partial
l
oad and full load;
9 - Check of the heating safety systems:
- safety device for maximum temperature (overheat
thermostat);
- safety device for maximum pressure (safety valve);
10- Check of the gas safety systems:
- safety device for lack of gas or flame ionisation (detection
electrode);
11- Check of the electrical connection (ensure it complies with the
instructions in the manual);
12-
Check of Domestic Hot Water production efficiency (flow rate
and temperature);
13- General chec
k of the comb
ustion by-products of the
discharge/ventilation system
14- Check of the general performance of the unit.
5. MAINTENANCE