Technical information

21
IS
THERE STILL
A PROBLEM?
FUNCTIONS
NORMALLY
NO
YES
LIST OF PROBLEMS POSSIBILE CAUSES
1
2
3
4
5
6
7
8
D
Delivery of hot water for domestic use:
when the tap is turned on, the bumer
goes out.
Delivery of hot water for domestic use:
the radiators are heated in summer mode
Delivery of hot water for domestic use:
water temperature is not satisfactory.
Delivery of hot water for domestic use:
noisy operation.
Drop/increase in pressure in primary
circuit.
Repeated shutdowns.
Safety thermostat is triggered repeatedly.
Temperature of radiators not satisfactory.
- air in secondary heat exchanger
- faulty main circuit flow switch
- faulty D.H.W. probe
- faulty 3-way valve
-
check sensor for domestic and heating water
- check gas settings and regulation
- check water flow rate
- check DHW storage
- primary exchanger is defective
- low water pressure in heating system
-
check gas settings and regulation
-
check D.H.W. probe
- check for leaks in heating circuit
- defective water filling loop
- check DHW storage
- expansion vessel is empty
- faulty detection electrodes
-
check gas settings and regulation
- check electric circuit for flame detection
-
Faulty (contacts) ntc sensor-heating/hot water
- Defective (poorly calibrated) safety thermostat
- Presence of air in the primary water circuit
- check ntc sensor for heating
- check by-pass
- check gas settings and regulation