Electrical Connection
The electrical connection to the mains must be made on 
the appliance. The power voltage and frequency are as 
indicated on the rating plate.
! THIS APPLIANCE MUST BE EARTHED.
Fitting the power supply cable
1. Open the terminal board 
by inserting a screwdriver 
into the side tabs of the 
cover. Use the screwdriver 
as a lever by pushing it 
down to open the cover (see 
diagram)
.
2. Install the power supply 
cable by loosening the 
cable clamp screw and the 
three wire contact screws  
L-N-
.
Connect the wires to the 
corresponding terminals: 
the Blue wire to the terminal 
marked (N), the Brown wire 
to the terminal marked (L) 
and  the  Yellow/Green  wire 
to the terminal marked 
(see diagram).
3. Secure the cable by fastening the clamp screw.
4. Close the cover of the terminal board.
Connecting the supply cable to the mains
Install a standardised plug corresponding to the load 
indicated on the data plate (see side). 
The appliance must be directly connected to the mains 
using an omnipolar circuit-breaker with a minimum contact 
opening of 3 mm installed between the appliance and the 
mains, suitable for the load indicated and complying with 
current electrical regulations (the earthing wire must not be 
interrupted by the circuit-breaker). The supply cable must 
not come into contact with surfaces with temperatures 
higher than 50°C.
! The installer must ensure that the correct electrical 
connection has been made and that it is compliant with 
safety regulations.
Before connecting to the power supply, make sure that:
•  The appliance is earthed and the plug is compliant with 
the law.
•  The  socket  can  withstand  the  maximum power of the 
appliance, which is indicated on the data plate (see 
below).
•  The voltage must be in the range between the values 
indicated on the data plate (see below).
•  The socket is compatible with the plug of the appliance. 
If the socket is incompatible with the plug, ask an 
authorised technician to replace it. Do not use extension 
cords or multiple sockets.
N
L
! Once the appliance has been installed, the power supply 
cable and the electrical socket must be easily accessible.
! The cable must not be bent or compressed.
! The cable must be checked regularly and replaced by 
authorised technicians only (see Assistance).
! The manufacturer declines any liability should these safety 
measures not be observed.
APPLIANCE SPECIFICATIONS
Dimensions*
width 43.5 cm 
height 32,4 cm 
depth 41.5 cm
Volume*
59 l
Dimensions**
width 45.5 cm 
height 32,4 cm 
depth 41.5 cm
Volume**
62 l
Electrical 
connections
voltage: 220 - 240 V~ 50/60 Hz or 
50 Hz (see data plate) 
maximum power absorbed 
2800 W 
ENERGY 
LABEL
Directive 2002/40/EC on the label 
of electric ovens. Standard EN 50304
Declared energy consumption 
for Forced convection Class – 
heating mode:
ECO.
* Only for models with drawn rails.
** Only for models with wire rails.
This appliance conforms to the following 
European Economic Community 
directives: 
- 2006/95/EEC dated 12/12/06 (Low 
Voltage) and subsequent amendments. 
- 2004/108/EEC dated 03/05/89 
(Electromagnetic Compatibility) and 
subsequent amendments.
- 93/68/EEC dated 22/07/93 and 
subsequent amendments. 
- 2012/19/EC and subsequent 
amendments.
- 1275/2008 standby/off mode.