Use And Care Manual

16
EN
Figure 11 - High Limit Switch Reset Detail
18 / 27kW Model
36kW Model
B. Checking Thermostat Operation
To check thermostat operation:
Press the button to activate the heater. The display will show the outlet temperature.
With the water running through the unit, press to increase or to decrease the outlet temperature. The
recommended temperature setting is 118
o
F (48
o
C). NOTE: A lower setting is more economical and reduces
the risk of scalding.
C. Changing the Heating Element
Turn o the power supply and drain the water heater (see
procedure, this manual).
Remove heating element (see procedure, this manual).
Install new element with new red O-Ring, making sure the
O-Ring and element are positioned correctly. Tighten the
retaining cap and wire connections. See Figure 12.
Reinstall the water heating assembly. When reinstalling,
work in the opposite way of the procedure.
Rell the water heater with water before restoring power.
D. Changing a Triac
Turn o the power supply.
Disconnect the three (3)
wire connectors on the
triac. Remove the wires.
See Figure 13.
Remove the two (2)
screws connecting the
triac to the inlet. Remove
the triac.
Install the new triac and
re-attach the wiring and
screws.
Insert
New
Heating
Element
Close
Cover
Reconnect Wires
Insert New
Red O'Ring
Figure 12 - Installing an Element
Remove
Triac
Install
New Triac
Torque: 1.2Nm
Step 1
Step 3
Step 5
Step 2
Step 4
Step 6
Figure 13 - Changing a Triac
NOTE: After adjusting the water temperature, allow the heater
enough time to heat the water to temperature. Then use a
thermometer to measure the water temperature at a hot water
outlet in the structure.