Initial operating procedures
Check the water pressure on the pressure gauge and make sure
that the gure is between 0.6 and1.5 bar when the system is cold.
If the pressure is just under the minimum value the display will
request a lling procedure - see note below.
Re-establish the correct pressure by lling loop.
If the pressure drops very frequently, there may be a water leak
at some point in the system. If this is the case a plumber should
be contacted.
FILLING PROCEDURE
AirPurgeActive
Note: Connections viewed from behind boiler
1. To repressurise the system ensure exible hose 3 is
connected
2. Slowly open taps 1 & 2 (see diagrams above)
3. Water will be heard entering the system
4. When the pressure gauge reads 1.5 bar close taps 1 & 2
1
2
3
Note.
Connections viewed from
behind boiler.
DISPLAY
Date and time
26/10/15 12:30
Keylock active
D.H.W. set temperature and indication of
the set temperature level
42°
C.H. set temperature and indication of the
set temperature level
Warning scheduled maintenance
Heating operation set
Heating operation active
D.H.W. operation set
D.H.W. operation active
Flame detected with indication of power
used
Digital pressure gauge (bar)
Scrolling text displaying operation as
information
Centralheating
Error wsignals
The display show the code and
description
ALERT
AUTO function activated
AUTO
Hot Water Comfort activated
COMFORT
CH Schedule programming
(set display: boiler base - see user’s menù)
CH Schedule programming
(set display: boiler complete - see user’s menù)
Internal temperature displayed for
set zone. (with bus device connected
- optional)
External temperature displayed
ECO mode
WIFI active
WIFI connected to the local network,
but without access to the server
WIFI not congured
Solar temperature probe connected -
option
26/10/15
1,5 bar
AUTO
Riscaldamento attivo
COMFORT
12:30
60° 82°
10°
20,5°
3
00 02 04 06 08 10 12 14 16 18 20 22 24